Search: Grundig
Results: 948
Make Model Symptom Problem Solution By
GRUNDIG 26-9940T VISION9
SU
It takes a while to turn on, but when it does turn on it works normally. If we turn it off after a while and turn it on again, it turns on quickly Voltage regulator IC902 1.2V (MP2112) Replace integrated circuit Mário Santos
GRUNDIG 32LXW82-8630
B/w image Change crystal 20,250 Rui
GRUNDIG 32LXW82-8630
B/w image Change crystal 20,250 Rui
GRUNDIG XENTIA 32LXW82-8625
The LED blinks but does not start Change all electrolytics in the power supply Rui
GRUNDIG 23LW60-7510
Try to start. does not have backlight Reverse with problems I replaced the inverter board Cesar12
GRUNDIG 40VLE6142 C
Turns on normally and after 1 minute the backlight turns off LED bar with a shorted LED. Cesar12
GRUNDIG 55VLX7810BP
KT-Chassis
No image but with backlight Verify replace c435 na t-con Marco Marques
GRUNDIG CUC6300
The screen was "clean", white without "rain", no image, no sound, no go command Zc8864 processor clock problems After all, the problem returned as suspected. I replaced the "crystal" but that didn't solve it either. Júlio Silva
GRUNDIG CUC6300
CUC6300
The screen was "clean", white without "rain", no image, no sound, no go command Zc8864 processor clock problems Resolder c821, c822 and f821. it started working. I don't have the f821 to replace, but it solved it! Júlio Silva
GRUNDIG VLE6142
Bad image, half screen Lots of changes, lots of changes. Mário oliveira
GRUNDIG 3221 CUC6880
CUC6880
When you connect the antenna the TV turns off C517 and c516 with loss of capacity or cold welding José Silva
GRUNDIG C2105 S815 CUC41KT
CUC41KT
Dead, doesn't start Power input shock José Silva
GRUNDIG 23LW60-7510
It doesn't start, it always stays on standby I just solved it by replacing the inverter Mário Martins
GRUNDIG 26LXW 68-8600 32LXW 82-8600
LX
Does not work, 24v supply without voltage Condenser c2056(100µf/50v) swollen Mário Martins
GRUNDIG 42PW110-6605
Power supply relay audible but does not turn on, not even the power-on LED Check r1021(33ω smd), ic1005 - ic1006(tl431), rectifier bridge d1001, ic1004(fsd200), and the fuse fs1001 (3.15a) Jocix
GRUNDIG ST 55-906 FR/DOLBY
CU2021 F
Stby -> load in p+ -> image tries to open but does not open -> stby Vertical shorted. protection comes into operation and prevents the TV from turning on. Replaced the tda8356 and it's back to normal. Replace tda8356 Filipe
GRUNDIG 32LXW 82-6710
G BF 49.00
No image, 24 volts low D905-d906 (sms) with an almost imperceptible leak Charlie
GRUNDIG MFW70-2501/8
BEKO C7-C8
Queue of For this situation, tsound are several possible causes: l503 with signs of overheating, r516 4r7/1w open. capacitors c623 680uf/16v and c522 1uf/160v must also be checked. Replace t504 2sd2499 (=bu2520dx) l503 and r516 4r71w; replace c623 and c522 Electrohd
GRUNDIG LENARO 55 FLAT
K2
Does not turn on, LED flashes C651 no capacity asteixeira
GRUNDIG P37-040
CUC5300
LED only lights up quickly flashing Brighten Ernesto Figueiredo