GRUNDIG CUC2103
CUC2103
No vertical linearity (image cut off at the bottom of the screen) Zener diode 5.6v 1w position d50048 Raimber
GRUNDIG 32LXW82- 8600DL
LX BEKO
Power supply without 24v - xla-194-03 C2048 (680uf/35v) tvtronica
GRUNDIG MFW 82-2510
22.2
Horizontal amplitude too open Substituir, c521 33nf 630v, d505 f60b5ads divercentro
GRUNDIG P37-4501
E3
No image no sound completely blue all menus working normally. C163 47n cc sanitron
GRUNDIG T55-830 CUC7303
Image does not fill the screen voltage + b varies a lot and turns off the power supply with variations in the video signal or variations in the network Replace the 0.56Ω resistors r667 may be altered Corvo
GRUNDIG T70-440
CUC4410
Very weak antenna signal, screen with drizzle Change the tuner and redo welding on its docking base The image amplitude was also adjusted Nezocas
GRUNDIG MF55-2501/5 TOP+
16.1
Doesn't start Fusivel of Causes ptc (090q ksn81), shorted joaquim cunha
GRUNDIG ST70-809/9
CUC6360
Turns on without sound, does not increase the sound In the int of on/of the temporary contact Replace r104 (470k by 47k) joaquim cunha
GRUNDIG T55-2401 TEXT
E1
No voltage from g2 Replaces the transfer lines per hour 80062 and already has g2 voltage but with defective colors Americo pereira
GRUNDIG GDP-1400
Doesn't turn on anything, no voltage on the secondary C111, 2200mf/10v. u901, ice2a0565 Replace capacitor on secondary and ci on primary S.O.S. Electrónica - Fundão
GRUNDIG CUC5303
Swapping tda8214 for tda8215 (no sound) Change r522 from 47k to 39k and remove r529 António Correia
GRUNDIG T51-060
CUC6300
Horizontal very open, r572 open Replace r572, c573 and c574 Replace r572, c573 and c574 gloop
GRUNDIG ST55-908/8 DOLBY
CUC2121
Turns on does not start (stby) Ic vertical (tda8174) Ver c53054 (1μF/100v), br81053 (2,2r) JOAQUIM CUNHA
GRUNDIG MW70-2699NIC/T0P
CUC2059
Does not turn on; led off Fusivel si62501 (2ap/250v) ; ptc (t209) joaquim cunha
GRUNDIG P37-060
CUC6300
Vertical closed Open r591 and tda8174w with pin 1 in dc Subst r591 por 0 .68r tda8174w camane
GRUNDIG T-55 830 TEXT
CUC 7303
White line in the middle of the screen Vertical deflection failure Tda 7303 replacement Ruca23
GRUNDIG 8214
Color bars on the screen approximately 5cm wide Cond. electrolytics 4.7uf/63v without capacity (one in each video output) SIMP
GRUNDIG CUC 2103
CUC 2103
It tries to start and then goes to standby, increasing the screen and there is a horizontal stripe when it tries to start! Ic 50010 (vertical IC tda1771) shorted, r54006 open Replace ic50010, r54006, c52002, c63054 (electrolytic next to ic do vertical) CarlosVale
GRUNDIG CUC6300
CUC6300
Intermittent image loss, loss of image and loss of sensitivity (white screen) T936/bc548 flashing Replace t396/bc548 SIMP
GRUNDIG M55-5501
K2
Image two seconds later goes into standby sometimes lasts two or three hours C651 low capacity d611 leaking obombeiro