Search: philips
Results: 14209
Make Model Symptom Problem Solution By
PHILIPS MD1.1A
How to enable/disable "child lock" Select "features" (this expression is language dependent) menu on remote control. within "features", the "child lock" can be enabled or disabled.
PHILIPS MD1.1A
Error in service manual md1.1a (4822 727 21523) Error in service manual md1.1a (4822 727 21523) table 8.9 on page 47 of the service manual contains errors. a number of sets is fitted with a toshiba lavender mask crt. the 3rd option code for these sets is stated incorrectly in the service manual.
PHILIPS MD1.1A
Cracking sound on some channels Replace item 2404 on the audio module by a 3.3nf 5% 50v capacitor (order code: 5322 122 33446) remarks :this modification is implemented in production from week 9727 onwards.
PHILIPS MD1.1A
Correction to styling 217 of product survey 1999-3 (3122 785 10300) The code number of position 12 of styling 217 is not correct. the correct codenumber for position 12 is 4822 240 10346.
PHILIPS MD1.1A
Correction on product survey styling 157 (md1.1a) Correction on product survey styling 157 (md1.1a) the mentioned service codes for items 13 and 15 are not correct. item 13 and 15 are supplied as one assembly. the order code of this assembly is: item service code description 13/
PHILIPS MD1.1A
Component change Component change item 7480 on the large signal panel has changed from: old 4822 130 63726 mtp3055efi to: new 4822 130 11336 stp16ne06fp remarks :this change is implemented in production from week 9839 onwards.
PHILIPS MD1.1A
Colour spot during switch off Replace item r3392 on the crt panel by a jumper. remarks :this modification was introduced in production from week 9727 onwards.
PHILIPS MD1.1
Dead with faint tripping heard with led flashing red/orange/green every 2 seconds I²c bus fault - sda line held low; caused by the tuner
PHILIPS MD1.1
Bad focus or focus varies in a new set or after crt replacement Possible solution: short circuit the focus and the g2 pins of the picture tube with the aquadag coating. switch the set on for approximately 5 seconds. after this return the set to its original condition. check if the focus adjusted normally. if not repla
PHILIPS MD1.0A
Repair kits available Repair kits available in order to easily repair line and smps problems, two universal repairs kits are available for the following chassis: chassis region md1.0a 4:3 & 16:9 asia pacific & latam md1.1e 4:3 & 16:9 eur
PHILIPS MD1.0A
No synchronisation with off-air (arial) picture Check and replace if necessary: item description (new) order number 2122 220nf 25v 20% 4822 126 13061 on the small signal panel. remarks :iris symptom code: f361
PHILIPS MD1.0A
No synchronisation on av (input) signal Check and replace if necessary: item description (new) order number 2115 220nf 25v 20% 4822 126 13061 on the small signal panel. remarks :iris symptom code: f361
PHILIPS MD1.0A
No raster Check and replace if necessary: item description (new) order number 2137 220nf 25v 20% 4822 126 13061 on the small signal panel. remarks :iris symptom code: 1316
PHILIPS MD1.0A
Microprocessor survey md1.0a Microprocessor survey md1.0a software family...version...ident...service code...last version pal/multi 4x3 4.4 3315 4822 900 14885 v4.6 (4.5..3353 4822 900 10968) (4.6...3448 4822 900 11073) ntsc korea 4x3
PHILIPS MD1.0A
Md1.0a supplement errata (4822 727 21506) Errata md1.0a aa supplement (4822 727 21506) there is an error in diagram c on page 6. position number 3376 (location l 10) should be 3380.
PHILIPS MD1.0A
Easy way to check the power supply Easy way to check the power supply---------------------------------- the mc44603 can be checked for basic operation without the set being connected to the mains supply. method: 1) discharge the 300v smoothing capacitor. 2) connect a byd33d diode to p
PHILIPS MD1.0A
Clock inaccurate Check and replace if necessary: item 1650 an improved 8mhz crystal (4822 242 10364). remarks :this solution is implemented in production from week 9727 onwards.
PHILIPS MD1.0A
Bad focus or focus varies in a new set or after crt replacement Possible solution: short circuit the focus and the g2 pins of the picture tube with the aquadag coating. switch the set on for approximately 5 seconds. after this return the set to its original condition. check if the focus adjusted normally. if not repla
PHILIPS LO1.1E/2E
Service mode entering Enter 062596 then osd/status button on handset. arrow up/down to access req adj, arrow right/left to adjust, standby to store. make sure chan 6 is tuned to a chan or test pattern as set ends up on chan 6.
PHILIPS L9H.2E AA
Correction to service manual l9h.2e aa In the parts list of the service manual only the service code of the complete clock panel is mentioned. below also the service codes of the separate components are listed. 1072 3119 108 51861 clock panel complete (small led's) dp1 4822 265 30734 co