PHILIPS CTO
Dark screen defect I checked the luminance ci but it didn't solve the problem, the solution is to change the 150uf electrolytic capacitor c221, you can replace it with a 220uf one.
PHILIPS CTO
Intermittent defect you only hear a meow. Solution: resolder all the pins on the flyback and base plate if necessary
PHILIPS CTO
Tuning problem I couldn't make a perfect tune, there seemed to be interference with the image on the screen and when changing channels, it seemed like the tune kept slipping away. I solved it by changing the s157 and s158 coils
PHILIPS 14GX 1618/78R
The defect is an all-white screen, full of lines, it's as if the screen is completely open. Causes open resistor r-3469. check the 180v voltage going to the kinescope board
PHILIPS GL-1045
Total inoperative Probable cause d-345 zener take the test outside.
PHILIPS 12TX-1572
Unstable vertical deflection Probable cause change c-527 100uf. electrolytic capacitor
PHILIPS GL-1011
Vertical treme treme Replace the vertical output with an original one, if that doesn't work, change the filter electrolytics in the power supply and connected to the vertical output.
PHILIPS CN-4065
No color You can change ci 200, analyze all the components connected to it so there are no surprises.
PHILIPS CN-4065
Retraces at the top of the vertical screen. C-400 old electrolytic.
PHILIPS CN-4037
Defect retraces across the screen. C-400 change. put a new one
PHILIPS PHILIPS GL1013
Does not work, with a high-pitched whistle. I changed the fly-back and the problem was resolved. tip sent by: laureano
PHILIPS 14GL1319/78R
Off and has normal sound The 15µh 3738 shock was replaced on the tube plate.
PHILIPS MODELO CTO
Out of horizontal phase. Change the resistance r-878=120kΩ.
PHILIPS 20GL1343
Without +b general power supply with 20volts The vo-3340 power supply regulator trimmpot was replaced from - 470
PHILIPS 14GL1019/78R
Deleted without image. If you speed up the tube screen grid it lights up and there is no image. The sand-castle c-2309's 47pf capacitor with dc leak was replaced.
PHILIPS 20CN4465
The image shakes with feedback lines at the top of the screen The 390 pf capacitor c-406 was replaced.
PHILIPS 20GL1044
When it turns on it works normally but after a few moments it starts to blink and the screen goes off but the tube filament lights up Replaced part t-7205 ( bc 338 ) 9volt regulator of +b of ci tda 8361 and step to detect the defect: just check the 9volt +b and realize that the voltage was low.
PHILIPS 20GL1044
Does not change channels, fixed on channel 2, despite indicating on the screen the number of another channel. There was no supply voltage at pin 11 of the uv933, the defect was the open resistor r3958.
PHILIPS 20GL1045/78R
When you change channels, the color disappears and the horizontal falls: Replaced part transistor bc-338 7volt regulator, (which powers the f.i.) shorted. step to detect the defect: just check the 7volt +b and realize that the voltage was high.
PHILIPS MODELO:20GL1044 DEFEITO:
When turned on, it works with the vertical screen full of shutter-like glitches, but on the entire screen: Cold solder on the vertical deflector coil connection wires step to detect the defect: just pull the deflector coil wires hard and they loosen, and it comes from the factory inside an eyelet and the solder does not make perfect contact with the wires .