PHILIPS |
CTO
|
Dark screen defect | I checked the luminance ci but it didn't solve the problem, the solution is to change the 150uf electrolytic capacitor c221, you can replace it with a 220uf one. | ||
PHILIPS |
CTO
|
Intermittent defect you only hear a meow. | Solution: resolder all the pins on the flyback and base plate if necessary | ||
PHILIPS |
CTO
|
Tuning problem | I couldn't make a perfect tune, there seemed to be interference with the image on the screen and when changing channels, it seemed like the tune kept slipping away. I solved it by changing the s157 and s158 coils | ||
PHILIPS |
14GX 1618/78R
|
The defect is an all-white screen, full of lines, it's as if the screen is completely open. | Causes open resistor r-3469. check the 180v voltage going to the kinescope board | ||
PHILIPS |
GL-1045
|
Total inoperative | Probable cause d-345 zener take the test outside. | ||
PHILIPS |
12TX-1572
|
Unstable vertical deflection | Probable cause change c-527 100uf. electrolytic capacitor | ||
PHILIPS |
GL-1011
|
Vertical treme treme | Replace the vertical output with an original one, if that doesn't work, change the filter electrolytics in the power supply and connected to the vertical output. | ||
PHILIPS |
CN-4065
|
No color | You can change ci 200, analyze all the components connected to it so there are no surprises. | ||
PHILIPS |
CN-4065
|
Retraces at the top of the vertical screen. | C-400 old electrolytic. | ||
PHILIPS |
CN-4037
|
Defect retraces across the screen. | C-400 change. put a new one | ||
PHILIPS |
PHILIPS GL1013
|
Does not work, with a high-pitched whistle. | I changed the fly-back and the problem was resolved. tip sent by: laureano | ||
PHILIPS |
14GL1319/78R
|
Off and has normal sound | The 15µh 3738 shock was replaced on the tube plate. | ||
PHILIPS |
MODELO CTO
|
Out of horizontal phase. | Change the resistance r-878=120kΩ. | ||
PHILIPS |
20GL1343
|
Without +b general power supply with 20volts | The vo-3340 power supply regulator trimmpot was replaced from - 470 | ||
PHILIPS |
14GL1019/78R
|
Deleted without image. | If you speed up the tube screen grid it lights up and there is no image. The sand-castle c-2309's 47pf capacitor with dc leak was replaced. | ||
PHILIPS |
20CN4465
|
The image shakes with feedback lines at the top of the screen | The 390 pf capacitor c-406 was replaced. | ||
PHILIPS |
20GL1044
|
When it turns on it works normally but after a few moments it starts to blink and the screen goes off but the tube filament lights up | Replaced part t-7205 ( bc 338 ) 9volt regulator of +b of ci tda 8361 and step to detect the defect: just check the 9volt +b and realize that the voltage was low. | ||
PHILIPS |
20GL1044
|
Does not change channels, fixed on channel 2, despite indicating on the screen the number of another channel. | There was no supply voltage at pin 11 of the uv933, the defect was the open resistor r3958. | ||
PHILIPS |
20GL1045/78R
|
When you change channels, the color disappears and the horizontal falls: | Replaced part transistor bc-338 7volt regulator, (which powers the f.i.) shorted. step to detect the defect: just check the 7volt +b and realize that the voltage was high. | ||
PHILIPS |
MODELO:20GL1044 DEFEITO:
|
When turned on, it works with the vertical screen full of shutter-like glitches, but on the entire screen: | Cold solder on the vertical deflector coil connection wires step to detect the defect: just pull the deflector coil wires hard and they loosen, and it comes from the factory inside an eyelet and the solder does not make perfect contact with the wires . |