PHILIPS |
20PT424A/78R
|
Blue fabric | Ci 8305 | ||
PHILIPS |
20GL 1342
|
Black band on the left side of the screen (as if you had adjusted the horizontal to one side | Tda8361 3y | If we turn off the c2219 it seems that the defect is in it | |
PHILIPS |
29PT 854A/78R
|
When we raise the volume it goes down on its own | Driving on the control board on top of the TV | Clean with isopropyl alcohol | |
PHILIPS |
14GL 1013
|
Blue screen with retrace | R3710 18k | Kinescope board | |
PHILIPS |
20GL 1044
|
Flashing red | Rook 13 | ||
PHILIPS |
20PT424A/78R
|
Blue fabric | Ci 8305 | ||
PHILIPS |
20GL 1342
|
Black band on the left side of the screen (as if you had adjusted the horizontal to one side | Tda8361 3y | If we turn off the c2219 it seems that the defect is in it | |
PHILIPS |
A8
|
Turns off by itself | Cold probe solution on pin 13 trafo 5912. sp611 joaquim date 11/19/01 | ||
PHILIPS |
A8
|
No contrast | Defect pci combi filter 10/31/01 pe 614 | ||
PHILIPS |
L9.2AA
|
Works and then burns complete power supply | T5545 open c2529 short 10/17/01 flaviano technician posted pi 310 | ||
PHILIPS |
L9-SS
|
No image and/or sound | R 3258 and r3322 open 10julh01 joaci ba410 | ||
PHILIPS |
L9-SS
|
Characters with shadow | Check diodes 6213, 6214 and 6215 10julh01 joaci ba410 | ||
PHILIPS |
Z5
|
Vertical closing intermittent. | Check capacitors c206, c208, c682. * 16jull99 jdn *. | ||
PHILIPS |
Z5
|
Vertical running (sync2). | If it occurs after heating, replace the 9v regulator ic401. * 30may00 scn1298 *. | ||
PHILIPS |
Z5
|
Pip with dark screen. | When the day appears, the pip screen darkens. change r903 from 390 to 330. *05Aug98 h.desk* | ||
PHILIPS |
Z5
|
Does not accept remote commands | In service mode, correct the address value "00" to 00. *05Aug98 h.desk* | ||
PHILIPS |
Z5
|
Horizontal lines (bottom or top). | Change the value of resistor r522 from 22k to 8k2. *05Aug98 h.desk * | ||
PHILIPS |
Z5
|
Func. for a certain time (see desl4) | Stops working after some time and heats up r599 and q503. replace t502 and r599(changed). *05Aug98 h.desk* | ||
PHILIPS |
Z5
|
Turns off after some time of use. | It stops working after some time and r599 and q503 heat up. replace t502 and r599(changed). *05Aug98 h.desk* replace d411 with 1n4148. * 16Jul99 acm *. | ||
PHILIPS |
Z5
|
With a dark bar in the center | With a bar or distortion in the middle of the screen (fold). check d502. *05Aug98 h.desk* |