PHILIPS 20PT424A/78R
Blue fabric Ci 8305
PHILIPS 20GL 1342
Black band on the left side of the screen (as if you had adjusted the horizontal to one side Tda8361 3y If we turn off the c2219 it seems that the defect is in it
PHILIPS 29PT 854A/78R
When we raise the volume it goes down on its own Driving on the control board on top of the TV Clean with isopropyl alcohol
PHILIPS 14GL 1013
Blue screen with retrace R3710 18k Kinescope board
PHILIPS 20GL 1044
Flashing red Rook 13
PHILIPS 20PT424A/78R
Blue fabric Ci 8305
PHILIPS 20GL 1342
Black band on the left side of the screen (as if you had adjusted the horizontal to one side Tda8361 3y If we turn off the c2219 it seems that the defect is in it
PHILIPS A8
Turns off by itself Cold probe solution on pin 13 trafo 5912. sp611 joaquim date 11/19/01
PHILIPS A8
No contrast Defect pci combi filter 10/31/01 pe 614
PHILIPS L9.2AA
Works and then burns complete power supply T5545 open c2529 short 10/17/01 flaviano technician posted pi 310
PHILIPS L9-SS
No image and/or sound R 3258 and r3322 open 10julh01 joaci ba410
PHILIPS L9-SS
Characters with shadow Check diodes 6213, 6214 and 6215 10julh01 joaci ba410
PHILIPS Z5
Vertical closing intermittent. Check capacitors c206, c208, c682. * 16jull99 jdn *.
PHILIPS Z5
Vertical running (sync2). If it occurs after heating, replace the 9v regulator ic401. * 30may00 scn1298 *.
PHILIPS Z5
Pip with dark screen. When the day appears, the pip screen darkens. change r903 from 390 to 330. *05Aug98 h.desk*
PHILIPS Z5
Does not accept remote commands In service mode, correct the address value "00" to 00. *05Aug98 h.desk*
PHILIPS Z5
Horizontal lines (bottom or top). Change the value of resistor r522 from 22k to 8k2. *05Aug98 h.desk *
PHILIPS Z5
Func. for a certain time (see desl4) Stops working after some time and heats up r599 and q503. replace t502 and r599(changed). *05Aug98 h.desk*
PHILIPS Z5
Turns off after some time of use. It stops working after some time and r599 and q503 heat up. replace t502 and r599(changed). *05Aug98 h.desk* replace d411 with 1n4148. * 16Jul99 acm *.
PHILIPS Z5
With a dark bar in the center With a bar or distortion in the middle of the screen (fold). check d502. *05Aug98 h.desk*