Make Model Symptom Problem Solution By
SHARP DV5103
Lin fault , or low def pic or loss mem , tuning , so Ic1411 nvm sharp ch-ix1409cjho
SHARP DV5103
Dist sound playing back vhs hifi using a/v ip.chan 10k resistors are fitted , from neg side c1374 to deck , from neg side c1372 to deck , from neg side c1394 to deck , from pos
SHARP DV5101H
Wont come out of sby R612 open - change r612 with 2.2Ω and fit r612 2.2Ω sharp -xz0204bmzz , j-13 1.2Ω sharp vrd-ra2hd1r2j
SHARP DV5101H
St/by only Ht high at 170v (113v), opto cnx82a faulty but still no go - link 147 in 25v line was o/c (an inductor) fitted wire link in lieu & now ok
SHARP DV5101H
Dead with smell of burning R705 overheating - d708 s/c
SHARP DV5101H
Dead maybe smell of burning d708 s/c r705 o/c Sharp issue repair kit
SHARP DV5101 DV5103
Stuck in stby: no vertical drive: colour faults: d All can be caused by ic1400 vsp replace ptn rhix426bmzz
SHARP DV5101 DV5103
Stuck in stby : pic distortion : white pic : no os All can be caused by ic1404 tvpo replace ptn rhix1443bmn5
SHARP DV5101
No st/by Chopper tfmr hi res on 5v winding
SHARP DV3770H
To access service mode Link pins 3 & 6 of conn tb & press "mode" on r/c. "service" appears; select with "mode+ & -", adj with "chan+ & -"
SHARP DV3761H 4BSA
Field int C512 82nf field ramp/charging cap to pin 6 ic801 int
SHARP DV3760H 4BSA
No start up C604 1000mfd 16v o/c
SHARP DV3760H 4BSA
Dead but all psu secs ok apart from 13v D602 faulty tho' measured ok
SHARP DV3760H
Vertical stripes on left side esp dark scenes Fit 1k8 in place of jumper wire r895 sharp vrd-ra2hd182j
SHARP DV3760H
Dead with s/c across line o/p transistor Check d601 1n4937
SHARP DV3760H
Dead - no o/p from psu D601 1n4997 ht rect leaky
SHARP DV3760H
Dead S/c across lop stage; d601 1n4937 600v 1a s/c
SHARP DV3760 4BSA
Shuts down straight away at sw on Replace loptx (hr 7559) plus r649 27r 1/2w, r637 27r 1/2w, r640 56r 1/2 w + 2 elect caps between base/emitter q1010
SHARP DV3760
Tripping psu & led red/green flashing C604 1000µ 16v in sec of psu
SHARP DV3760
Pic displaced 3" to right R604 seems to be the cause (wrong value?) removing it centralised pic