Search:
Results: 87711
Make Model Symptom Problem Solution By
SONY KP5040
Intermittent mechanical operation, poor ground connection Intermittent door opening. s953 on the motor: one side ofswitch was not tight due to no threads.
SONY KP5020
Poor focus after warm-up After warm-up, picture would go out of focus. found redpicture tube focus shorting inside tube. this caused blue and green togo out of focus, since all three tubes (focus) are connected to the sameblock.
SONY KX2501A
Beat pattern in the picture, re-routed cables p2 and p3 There was a beat pattern in the form of a 1 inch vertical lineabout 2 inches in from left side, on ch. 7 only. moving the ac cordwhere it was connected to the d board would increase or decrease theproblem.
SONY KV5200
Raster with retrace lines Set came in with all white raster with retrace lines. audiowas ok.
SONY KV2654R
Picture up/down button stuck, replace s004/005/006 Picture up button was stuck. therefore volume up/down andpicture up/down or channel up/down would not work. found picture upbutton was worn. this switch was spring loaded in rather than out.
SONY KV2649R
Dark picture, open r541 and shorted c531 Dark picture, slight retrace lines. no screen voltage tocrt g2.
SONY KV2647R
No color, replace ic-501 Picture was dark and also had loss of color. scoping ic501pin 15, horizontal sync pulse was only 6 vpp - should be 11vpp. i haveseen other sets that displayed intermittent dark picture or change of hueonly. all are related to ic501 sync output. the s
SONY KV2647R
Vertical bars on the screen This unit had several vertical bars on the left side.
SONY KV2647R
Mechanical damage, q601 lead Leads of q601 are breaking due to mechanical stress. duringmanufacture, the leads are being stretched tightly before soldering.as the heat sink flexes during shipping, the leads break.
SONY KV2643R
H flagging on the top of the screen, replaced ic501 This unit had slight horiz. flagging at the top of the picturewhen using the still/slow features on an sl-2700. all other modes (offair, cable) worked fine as did other betamax and vhs power supplys. the onlyproblem was with the still/slow features on the sl
SONY KV1952RS
Dark picture and retrace lines, shorted c548 and open r555 Dark pix-retrace lines very faint. no screen voltage tog-2 of crt.
SONY KV1945RS
Sound distortion, replaced leaky c116 Intermittent, uncontrollable sound. remote inoperative.indicator light on at all times. all manual functions worked fine exceptpix and sound.
SONY KV1930R
Picture distortion, replaced ne701 on "c" board When the brightness and contrast controls are turned up(max. beam current), the picture intermittently flashes and produceslarge horiz. dark lines. we found ne701 on the crt board to be the cause.
SONY KV1913
Dead This unit initially was found to have a shorted regulator,regulator driver and power module. after replacement we found the b+ tobe low, about 105v. we found neon nl601 in the power supply to be thecause.
SONY KV1713
Snowy picture In the last 2 months the tuner was replaced three times,found c217 cap leaky. pix would go to snow.
SONY KV1510
Part's compatibility When subbing the 1-463-109-00 tuner with the 1-463-132-00,the channel indicator numbers go down when they should go up and viceversa. -hq comments: replace the original tuner. in addition you have to orderdial drums from kv-1511: s/m page 32, p/n 4-31
SONY KV1205
Intermittent shut down, replaced q509 Found q509 (hv protect) breaking down. replaced q509.
SONY FD210
No picture, resoldered c653 This unit had no picture and received fm stations instead oftv freq. a quick examination of the power supply revealed that the 14vand 40v (tuning) lines were very low (6v). we found the connection onc653 to be poor. this is the coupling capacitor betw
SONY VTX1000
No tuning operation Would not tune any channels. vc voltage to tuner remainedhigh. no pulses out of the ic001.
SONY KX2501
Intermittent shut down, replaced hv block Intermittent hv shutdown.