Search:
Results: 88147
Make Model Symptom Problem Solution By
SONY STRV25
Error in manual Page 7 procedure 2, error adjust rt101 for 76 khz +/- 100 hz.this is opposite str-v2/-v3/-v4.
SONY STRV25
Modification on mounting flame proof resistors Q652 failed causing flame proof resistors r633, 664, 665 tooverheat and open. this type resistor gets very hot before opening sincethese are mounted tight against the board. damage will occur when theyget hot.
SONY STRV5
Defective ic451 No output, meter and lights operating, relay activates. b+and b- low.
SONY STRV3
Error in service manual The schematic (page 20) shows bias test points incorrectly atcollector of q713 and q763. should be at emitters. -hq comments: see technical newsletter #8102.
SONY STRV2
Error in service manual Vco adjustment page 9, procedure 2, adjust rt201 for 19khz+/- 100hz error.
SONY ICFC310W
Modification for buzzer level Alarm level very low.
SONY ICFC11W
Clean and adjust switch Alarm set time shows upon auto buzzer.
SONY ICF7600
Loose dial indicator Dial indicator needle disconnects from the dial string. theunit will continue to tune radio stations but customer is unable to determine the station from the indicator.
SONY CFS71
Lubrication in switch assy needed When the fast fwd/rewind switch is activated by the switchlever assy, binding of the two nylon pieces can occur. this causes themuting switch to stay in the on position. the audio is then greatlyreduced. this condition occurs most often when the ams f
SONY CFM23
Defective motor Tape speed slowing - occasionally decrease in current tomotor. same decrease on external dc input.
SONY TFM7720W
Broken connection on control Volume control has no effect on volume - volume remains loud.removed volume control and it was working properly.
SONY TFM7720W
Cold solder No am on low end.
SONY TFM6160W
Loose pulley The tuning dial does not work. the pulley near the speakerpulls loose causing the dial string not to work.
SONY TCS300
Idler out of position Spindle assy take-up reel will not turn in playback or recordonly.
SONY TCK81
Back tension torque adjustment Back tension and tape path was incorrect. complaint of tape wrinkle on maxell tape.
SONY ICK81
Steel ball out of proper location Tape jammed. found head deck wouldn't retract properly.
SONY TCK65
Defective ic802 After operating approx. 1.5 to 3 hrs, the transport willstop - rewind - stop. the led display will then indicate 1 and none ofthe function switches have any effect. this is with rms off, with rms on- cannot be programmed. found pins 12, 13, 15, 16 of
SONY TCK5
Missing bushing Both of these units came in with excessive wow and flutter.what causes this is the absence of a bushing which holds motor switchlever in place. without this bushing motor lever is allowed to movefreely and ends up meshing with the teeth on supply gear c
SONY STRV55
Leaky c412 Am and fm very slow to lock on station - then drifts offagain. tantalum capacitor c412 in lpf was leaky.
SONY STRV45
Defective c412 Tuning incorrect - am station at 920 khz, tuned in at1600 khz. no local on 1600 khz. fm tuning out of band and picking upmicroprocessor rfi.