Make | Model | Symptom | Problem | Solution | By |
---|---|---|---|---|---|
SONY |
TCM121
|
Belt jumps off motor | Belt jumps off motor pulley due to lubricant getting on belt. | ||
SONY |
TAE5450
|
Transformer radiating 60hz | Hum in both channels. volume control had very little effecton control of hum. if volume control turned up, tone controls wouldeffect hum. | ||
SONY |
STRV2
|
Blown transistors | Several units came in with blown power fuses. | ||
SONY |
ICF7750W
|
Timer does not function | Timer will not cut off after activating. | ||
PHILIPS |
14PV162
|
Calling installation menu | The installation menu is activated by the following procedure: - switch on the set by means of the stop key. - press simutaneously the cursor left and the cursor right key on the remote control. | ||
PHILIPS |
14PT156B
|
No pic (field collapse) - sound ok | R3449 4r7 feed res to fop chip o/c - no other fault detected | ||
PHILIPS |
14HT3303
|
Service code of the fm-radio tuner. | In the partslist of the radio-sp/ls-vbatt panel of the chassis manual l9h.2e, the service code of the fm-radio tuner item 1901 was not indicated. the service code is 9352 632 70112 | ||
PHILIPS |
14CN3001/05
|
Int low contrast | Check preset res (chan scan) isn't shorting to crt aquadag | ||
PHILIPS |
14CN2201
|
Dead - correct 100v ht on dummy load | Scan coils - had arced across rubber wedge | ||
PHILIPS |
12TVCR240/05
|
St/by only - no line drive | Ug06b clamp diode leaky | ||
PHILIPS |
12B312/15S
|
Dead. | Drys on sub pcb & bu type regulator. | ||
PHILIPS |
10CX1120/05R
|
Power supply working but no line drive. | Changed the following t539 / t534 / r537 / r502. lopt faulty | ||
PHILIPS |
10CX1120/05
|
Raster - distorted & no frame sync. | Ske bridge recy. | ||
PHILIPS |
10CX1120/05
|
Dist raster & no field sync at sw on - clears aft 10 mins | Mains bridge rect int goes o/c | ||
PHILIPS |
10CX1120/05
|
Dead - micro tms3757anl-10 | T273 bc557 s/c in av/rf sw cct also | ||
PHILIPS |
10CX1120
|
Servicing the philips 10cx1120 | See tv mag jan 1995 | ||
PHILIPS |
10CX1120
|
Field scan erratic with cramping across centre | C582 10nf ceramic cap leaky - pin 20 tda1770 | ||
PHILIPS |
10CX1120
|
Field int cramps , sometimes collapses | C582 10nf on pin 20 tda1770 field ic | ||
PHILIPS |
10CX1120
|
Dead. | T9629 ( buz71 ) s/c , plus drys around loptx. | ||
PHILIPS |
10CX1120
|
Dead on battery - ok on mains | C23 1æ in psu - also d37 o/c causing 8v supply to be slightly high (did not affect operation) |