Make Model Symptom Problem Solution By
GRUNDIG CUC5360
Store ,tuning , analogue controls inoperative Check memory ics ic847/8 also bad earths which could be cause of ics going faulty
GRUNDIG CUC5360
No vid via scart skt Sw carried out in tuner/if chip. check ct2512/3/4/7 sm types bc848/858
GRUNDIG CUC5360
Int tuner Check for dry joints on xtal
GRUNDIG CUC5360
Col int Replace 4.43mhz red trimmer
GRUNDIG CUC5360
No nicam sound - whistle on mono sound Msp2400 chip in if module
GRUNDIG CUC5350 CUC5360
"p1" displayed after processor changed R836 from 10k to 22k ( old sda 20562 a 006 new sda 20562 a 506 grundig 8305-157-580 )
GRUNDIG CUC5350
White lines & 2 of each r-g-b- lines on top 3 ins of screen Check ht & replace c538 47u 35v
GRUNDIG CUC5350
No sound at sw on; if vol + on r/c operated sound returns for duration of button press Aerial socket loose was reputed to be the cause !!! (socket came adrift)
GRUNDIG CUC5310
Int pic 10v ripple on 200v ht line due to c681 4µ7 350v o/c
GRUNDIG CUC5310
Dead chopper sc when replaced blows again D681 sc
GRUNDIG CUC5310
Dead - t644 chopper tr s/c S1624 wickman fuse in 300v supply o/c, d681byv38 200v rect on sec psu s/c
GRUNDIG CUC5310
Dead - fuse si624 1.25at o/c T644 buz90 chopper tr s/c
GRUNDIG CUC5305
No i/p via scart Ic2350 tda5931-5 on if pcb
GRUNDIG CUC5303
Ps. transistor blown. changed chopper tr, and tda4605, but they were blown again. occasionally the set before blowing the smps may run for a while. Check/replace r632 270k resistor.
GRUNDIG CUC5303
No front or r/c controls aft couple of hours Ir rx
GRUNDIG CUC5301
R/c inop - no response from ir rx Replace ir unit tfms4300 4 leg type, with tfms5360 3 leg type not all 3 leg type will do
GRUNDIG CUC5301
Osd dim & outline only - ok when no sigs present Ic2541 tda3566 col dec chip u/s
GRUNDIG CUC5301
No r/c 4 pin rec u/s - replace with 3 pin version
GRUNDIG CUC5301
Int pic - sound ok Dry joints t568 tr heatsink - mech stressed
GRUNDIG CUC5301
Field collapse D401 12v zener s/c and hi ht due to 2 x 47µ caps