GRUNDIG CUC7301
Low sound -stuck in hotel mode Hold 'i' button whilst switching tv on. use rc arrows to select hotel mode then off
GRUNDIG CUC7301
Low sound & no set up menu In hotel mode - to exit - hold down "i" button at sw on
GRUNDIG CUC7301
Field lin poor, width reduced & ht only 100v R666 & 667 in psu 0r82 had risen to 1r5 (values depend on crt size)
GRUNDIG CUC7301
Dead - r542 10k or 13k o/c When replaced overheated again - crack in print by lopt
GRUNDIG CUC7301
Dead - lop tr s/c & replacement ran hot Ct169 bc858b buffer sm leaky
GRUNDIG CUC7301
Dead - chopper t665 blown plus - Ic630, d633 3v6 zener, d662 ba157, bridge rects d621-4 1n4007, r661 220r, r663 18r, 3 x sm diodes under psu sect, dry joints c669
GRUNDIG CUC7301
Dead C669 1000pf dry joints & burnt; mjf18004 t665 s/c; zd663 had 25r reverse resistance, d624/621 1n4007 mains rects s/c & uc3842an faulty
GRUNDIG CUC7301
Dead Dry joint c669 blows t665 & ic630
GRUNDIG CUC7301
Blown psu caused by r661 220r going hi res Also replaced ic630 uc3842, t665 mjfs8004, d663 3v6 zener
GRUNDIG CUC73
Won't start up D663 sc
GRUNDIG CUC720
Won't start, ps squeals, relay remains open. Change c655 100uf/25v cap.
GRUNDIG CUC720
Teletext - fault - picture shows at same time C2881 ( 1uf )
GRUNDIG CUC720
Purity. Th on small mains pcb , c601 ( 0.15uf , 250v )
GRUNDIG CUC720
No sound R2408 ( 3.3r ) on sub pcb , tba120t in if must be a 120t
GRUNDIG CUC720
No frame. C2768 ( 100uf ) leaky , r2771 ( 6r8 ) , field to tda2653.
GRUNDIG CUC720
Int. won't start, sound ok. Change all small electrolytics on vertical/horizontal pcb.
GRUNDIG CUC720
Dead - blown 2.5amp fuse. Bridge rectifiers/c d621 ( skbb380 ) can use a by179.
GRUNDIG CUC720
Dark on bright scenes. C2216 ( 1uf , 63v ) tda5500 in if or change can , c2541 ( 2.2uf
GRUNDIG CUC70KT
Tripping - starts up then trips. D471 s/c can use a by299.
GRUNDIG CUC70KT
No picture - sound ok - static on screen. Frame pcb r2756 ( 7r 1/4watt ) o/c if so ic tda2653a