Search: Grundig
Results: 948
Make Model Symptom Problem Solution By
GRUNDIG CUC95
Field collapse R2754 1m preset
GRUNDIG CUC95
Dead - bu208 s/c. R646 high.
GRUNDIG CUC7890
Focus poor C07 680pf 12kv leaky
GRUNDIG CUC7861
St/by only - started as line collapse R503 4r7 safety res, tda8350, d503 by228 s/c & t572 2sd1432 breaking down under load - also check d502, d438 33v zener
GRUNDIG CUC7861
Sound from bass speaker weak Ct4140 bc849c sm tr o/c
GRUNDIG CUC7861
Poor field,no tuning, no col, smeary pic 45v supply low due to r552 2r2 o/c
GRUNDIG CUC770
Line tearing Check or change c501 ( 1000uf , 25v )
GRUNDIG CUC7530
No h drive (bc848) which is used as a line protector.
GRUNDIG CUC740
Sound couldn't be reduced &"88" in display Mc144111 ic2335 on tuning pcb
GRUNDIG CUC740
Pulling/rolling with weak sync Replace 2 x 1µ caps & 1 x 10µ cap in if module
GRUNDIG CUC740
Pulling/rolling - weak sync 2 x 1µ & 1 10µ cap in if module
GRUNDIG CUC740
No adj of vol,col,contrast etc Ic2335 mc144111 inside if/tuner can
GRUNDIG CUC740
Lines across screen - no sound Adj r2741 on deflection pcb
GRUNDIG CUC740
Int sound Check if +g supply missing - if so check relay contacts
GRUNDIG CUC740
Int dead or int st/by C633 100µ 25v
GRUNDIG CUC740
Int dead D671 by299 in 5v supply int o/c
GRUNDIG CUC740
Int cutout , going to sby or dead D671 5v supply
GRUNDIG CUC740
Excess width D572 ske4g2/06
GRUNDIG CUC740
Dead - s1644 1.25a fuse blown T654 bu208a s/c - check for arcing at c634
GRUNDIG CUC740
Dead - comes on briefly when tapped Dry joints chopper tr and surroundings