Philips Repair Tips
Search: philips
Results: 14210
Results: 14210
Make | Model | Symptom | Problem | Solution | By |
---|---|---|---|---|---|
PHILIPS |
MD2.22E
|
Audio supply repair kit md2.2 | Audio supply repair kit md2.2 ----------------------------- for service now there is an audio supply repair kit available. this repair kit can be ordered with codenumber 4822 310 11086. | ||
PHILIPS |
MD2.22E
|
Alternating noise in wireless surround speakers | Alternating noise when (moving) objects are between the tv set and the wireless surround box can be solved by deleting r3153 (1k5) of module 1403 of the transmitter panel in the tv set. the components on module 1403 are not indicated but pointing the modu | ||
PHILIPS |
MD2.22E
|
Aci table filling stops when national geographic channel is found | Replace position 7202 on the txt & control module by: 4822 900 11102 software for non epg sets 4822 900 11066 software for -/58 sets 4822 900 11058 softwrae for epg sets remarks : iris symptom code 1262 | ||
PHILIPS |
MD2.22E
|
+5 v stand-by defective (also fuse 1580 defect) | First check the +5 v supply panel before replacing the fuse. when the +5 v panel is defective, it could be that the +5 v becomes too high, which will damage the circuitry. | ||
PHILIPS |
MD2.22E
|
"digital scan" does not appear in the picture menu | In the direction for use is mentioned that in the picture menu the function 'digital scan' can be switched off. however during the picture modes; super zoom, 14/9, 16/9, subtitles an automatic the function 'digital scan' does not appear in the picture me | ||
PHILIPS |
MD2.22AA
|
Lines on pic | Syscon/txt module connections to main pcb dry jointed | ||
PHILIPS |
MD2.22AA
|
Dead - led goes green for 15 secs then turns constant red | Micro 7200 faulty - not a job to get involved with if at all possible! | ||
PHILIPS |
MD2.22
|
Dead - mains switch faulty | Replace switch with improved type (coloured black). use old part no, philips will supply a new type | ||
PHILIPS |
MD2.22
|
N-s distortion | If no n-s board fitted, then fit this board (482221211564 (30 pounds+vat)) and remove links 9431, 9442, 9443, 9621 | ||
PHILIPS |
MD2.21E
|
Wrong txt characters on subtitles | Replace position 7202 on the txt & control module by: 4822 900 11102 software for non epg sets 4822 900 11066 software for -/58 sets 4822 900 11058 software for epg sets remarks : iris symptom code 1286 | ||
PHILIPS |
MD2.21E
|
Vertical stripes in picture | On the right side a 2.5 cm width dark band and on the left side a vertical stripe can be seen. check if the wires s11-l11 and s10-l10 do not touch c2368 on the ssp. if they touch c2368 bend them away from c2368. | ||
PHILIPS |
MD2.21E
|
Vertical shift and amplitude not stable (jumps). | Check pins of connector j13 on the ddp. look for badly soldered (oxidized) pins. solder pins if required. remarks : improved connectors introduced in production from week 9742 onwards. | ||
PHILIPS |
MD2.21E
|
Unstable moving, "waving" picture | Check on +5 v panel the soldering of c2530. also check and resolder pin 1,2,3, and 10,11,12 of connector v50 on the lsp. | ||
PHILIPS |
MD2.21E
|
Two vertical grey bars in picture | Bent flatcables s10/l10 and s15/l15 away from tda9143 (pos. 7352 on the ssp) | ||
PHILIPS |
MD2.21E
|
Totally inoperative, red led slowly flashing; +5v is 2,2v | Check/replace diode d6520 (1n5822; 5322 130 32677) on the +5v panel. | ||
PHILIPS |
MD2.21E
|
Totally dead | If the mains fuse (2 amp; 1501 on the mainsfilter panel) is defective, replace it by a 6.3 ampere hard break (4822 253 30467) | ||
PHILIPS |
MD2.21E
|
The time from txt is not read or with mistakes | Replace position 7202 on the txt & control module with: 4822 900 11102 software for non epg sets 4822 900 11066 software for -/58 sets 4822 900 11058 software for epg sets remarks : iris symptom code 1286 | ||
PHILIPS |
MD2.21E
|
The colours are switching during playback of mounted video tapes | The colours are switching during playback of mounted video tapes on several camcorders. in case a tda9143 is present on position 7352 on the ssp: - change position 7352 into a tda9141 (4822 209 90328) - remove position r3377 and r3378 (20m) from the ssp | ||
PHILIPS |
MD2.21E
|
The bottom left side of picture shows a green teletext symbol | The bottom left side of picture shows a green teletext symbol whether or not the teletext is switched on. subtitling is selected, but the subtitling page is not stored. switch off the subtitle function by pressing the subtitle knob on the remote cont | ||
PHILIPS |
MD2.21E
|
Switching off and on of the wireless surround speakers | Check and replace the following components on the power supply + amplifier panel in the active surround speaker if necessary: - position 2280 into 220uf (4822 124 40196) - position 3280 into 330k (4822 116 52272) remarks : iris symptom code 6544 |