PHILIPS MD2.22E 29PT9113
White box with line in it at bottom lhs of the screen Auto subtitle selected, but not being transmitted, turn off with button under flap on r/c
PHILIPS MD2.22E 29PT9113
No tuning R3568 56k 0.5w on large signal panel (+40v supply to tuner)
PHILIPS MD2.22E 29PT9113
Bright red raster R3351 120k o/c
PHILIPS MD2.22E 29PT9113
At switch on green led comes on for 10 seconds, then switches to standby (red) Micro m27c801100f1v00640
PHILIPS MD2.22E
At switch on set goes into protection mode Replace c2524 with 10uf
PHILIPS MD2.22E
Wrong txt characters on subtitles Replace position 7202 on the txt & control module by: 4822 900 11102 software for non epg sets 4822 900 11066 software for -/58 sets 4822 900 11058 software for epg sets remarks : iris symptom code 1286
PHILIPS MD2.22E
Vertical stripes in picture On the right side a 2.5 cm width dark band and on the left side a vertical stripe can be seen. check if the wires s11-l11 and s10-l10 do not touch c2368 on the ssp. if they touch c2368 bend them away from c2368.
PHILIPS MD2.22E
Vertical shift and amplitude not stable (jumps). Check pins of connector j13 on the ddp. look for badly soldered (oxidized) pins. solder pins if required. remarks : improved connectors introduced in production from week 9742 onwards.
PHILIPS MD2.22E
Unstable moving, "waving" picture Check on +5 v panel the soldering of c2530. also check and resolder pin 1,2,3, and 10,11,12 of connector v50 on the lsp.
PHILIPS MD2.22E
Two vertical grey bars in picture Bent flatcables s10/l10 and s15/l15 away from tda9143 (pos. 7352 on the ssp)
PHILIPS MD2.22E
Totally inoperative, red led slowly flashing; +5v is 2,2v Check/replace diode d6520 (1n5822; 5322 130 32677) on the +5v panel.
PHILIPS MD2.22E
Totally dead If the mains fuse (2 amp; 1501 on the mainsfilter panel) is defective, replace it by a 6.3 ampere hard break (4822 253 30467)
PHILIPS MD2.22E
The time from txt is not read or with mistakes Replace position 7202 on the txt & control module with: 4822 900 11102 software for non epg sets 4822 900 11066 software for -/58 sets 4822 900 11058 software for epg sets remarks : iris symptom code 1286
PHILIPS MD2.22E
The colours are switching during playback of mounted video tapes The colours are switching during playback of mounted video tapes on several camcorders. in case a tda9143 is present on position 7352 on the ssp: - change position 7352 into a tda9141 (4822 209 90328) - remove position r3377 and r3378 (20m) from the ssp
PHILIPS MD2.22E
The bottom left side of picture shows a green teletext symbol The bottom left side of picture shows a green teletext symbol whether or not the teletext is switched on. subtitling is selected, but the subtitling page is not stored. switch off the subtitle function by pressing the subtitle knob on the remote cont
PHILIPS MD2.22E
Switching off and on of the wireless surround speakers Check and replace the following components on the power supply + amplifier panel in the active surround speaker if necessary: - position 2280 into 220uf (4822 124 40196) - position 3280 into 330k (4822 116 52272) remarks : iris symptom code 6544
PHILIPS MD2.22E
Subpages not stored/updated in menubar Check whether jumper 4400 is present on txt-control panel. if not present, mount jumper. the location is between x-tal 1201 and txt ic7400. codenumber jumper: 4822 051 20008.
PHILIPS MD2.22E
Stand-by led flashing after start up Errors 47, and possible 69 are indicated. solution: on lsp probably hfb signal not present caused of defective r3609, 4k7, 4822 052 10472.
PHILIPS MD2.22E
Sometimes still picture occurs Check and replace if necessary ic7400/ic7441 (tda8753an; 4822 209 90528) on the feature box.
PHILIPS MD2.22E
Set switches to stand-by Change software into the v_3104 317 00890 (4822 900 11058) remarks : introduced in production from week 9737 onwards.