PHILIPS MD2.23E
How to access "customer service mode" Press "mute" (on remote control) and "menu" on the tv-set at the same time for 4 seconds. on screen a survey will be given with the status of the various settings of the current transmittor.
PHILIPS MD2.23E
Horizontal stripes in picture on high volume or ticking against set Check pins on connector o55 on the combfilter panel. look for badly soldered (oxidated) pins. resolder pins if required. remarks : improved connectors introduced in production from week 9742 onwards.
PHILIPS MD2.23E
Horizontal jitter or sync faults during text-dualscreen mode. 1. switch the set on and let the set warm-up for about 1 hour with the rear cover mounted and eventually covered with a cloth. 2. adjust l5465 in the following way: - turn l5465 to the left till the picture is out of sync. - turn l5465 to the rig
PHILIPS MD2.23E
Horizontal (colour or black/white) stripes Check the connector (o55) of the comb filter. solder on the small signal panel but also at the comb-filter pcb.
PHILIPS MD2.23E
Greek characters in teletext. Change software into the following version: non epg sets: v_3104 317 00860; 4822 900 11102 epg sets : v_3104 317 00890; 4822 900 11058 -/58 sets : v_3104 317 00870; 4822 900 11066 remarks : introduced in production from week 9737 onwards.
PHILIPS MD2.23E
Flashing red led, protection, intermitting failures. Check on +5 v panel the soldering of c2350. also check and resolder pin 1,2,3, and 10,11,12 of connector v50 on the lsp.
PHILIPS MD2.23E
Feature boxes in the repair procedure Feature boxes in the repair procedure ------------------------------------- the following feature boxes are now also in the repair procedure: 4822 212 11143 fbx3 smartic panic 4822 212 11198 fbx3 smartic limeric 4822 212 11204 fbx4 smartic limeric panic 4
PHILIPS MD2.23E
Extension cables Extension cables ---------------- service extension cables 4822 310 10674 can be used for servicing lsp and also for the feature box.
PHILIPS MD2.23E
Does not start, during 15 sec. green led on, then red led on. Replace software ic7202 on txt/control panel codenr.: 4822 900 11058 and 4822 900 11066 for /58 sets.
PHILIPS MD2.23E
Digital picture when dynamic contrast is on. Check and replace if necessary ai panel. ai s/l 4822 212 11202 ai s/p 4822 212 11161 ai s/l/p 4822 212 11203 ai p 4822 212 11162 ai l 4822 212 11378 ai s/l/p palplus 4822 212 11205 ai s/p palplus 4822 212 11209
PHILIPS MD2.23E
Correction to the md2.21e/md2.22e/md2.23e Correction to the md2.21e/md2.22e/md2.23e service manual -------------------------------------------------------- the code number of the line repair kit as mentioned on page 67 of the service manual md2.21e/md2.22e/md2.23e aa is not correct. the correct c
PHILIPS MD2.23E
Coloured circles in picture after switching on Replace on the lsp the following components: - r3502 from 10Ω into 2.2Ω (4822 052 11228) - r3531 from 2k2 into 4k7 (4822 116 52283) - c2513 from 100nf into 10uf (4822 124 41579) mounted with the - to the base of t7514 remarks : introduce
PHILIPS MD2.23E
Codenumber information Codenumber information ---------------------- codenumber software ic7202 on txt control panel sets without full epg (nextview) is 4822 900 11102 sets with epg (nextview) is 4822 900 11058 /58 sets with east europe language cluster is 4822 900 11066
PHILIPS MD2.23E
Change in osd function Change in osd function ---------------------- during production the osd function of the md2.2xe sets has been changed with the introduction of new software. the old situation was that by pressing the osd button for 5 seconds it was possible to change bet
PHILIPS MD2.23E
Bad start behaviour, on and st.by led flashing Change mains input voltage by a variac. when start problem increases with an input voltage that is only about 10% below normal, check or replace the supply optocoupler. with a good optocoupler an avarage set easily starts on 60% of normal mains voltage.
PHILIPS MD2.23E
Audio supply repair kit md2.2 Audio supply repair kit md2.2 ----------------------------- for service now there is an audio supply repair kit available. this repair kit can be ordered with codenumber 4822 310 11086.
PHILIPS MD2.23E
At switch on set goes into protection mode Replace c2524 with 10uf
PHILIPS MD2.23E
Alternating noise in wireless surround speakers Alternating noise when (moving) objects are between the tv set and the wireless surround box can be solved by deleting r3153 (1k5) of module 1403 of the transmitter panel in the tv set. the components on module 1403 are not indicated but pointing the modu
PHILIPS MD2.23E
+5 v stand-by defective (also fuse 1580 defect) First check the +5 v supply panel before replacing the fuse. when the +5 v panel is defective, it could be that the +5 v becomes too high, which will damage the circuitry.
PHILIPS MD2.23E
"digital scan" does not appear in the picture menu In the direction for use is mentioned that in the picture menu the function 'digital scan' can be switched off. however during the picture modes; super zoom, 14/9, 16/9, subtitles an automatic the function 'digital scan' does not appear in the picture me