Search: philips
Results: 14209
Make Model Symptom Problem Solution By
PHILIPS MD1.2E 28PW6332
Low width & e/w faulty aft repair of dry joints in lop Enter service mode and setup e-w and nicam/text mode
PHILIPS MD1.2E 28PT6773
Pic remains in st/by - sound mutes ok Resistor 3588(lt supply) o/c, capacitor 2561 very low capacitance. replace 3588(3r3) and 2561(3300mfd).
PHILIPS MD1.2E 28PT4523/25
Tripping C2433 1n5 2kv burnt up
PHILIPS MD1.2E 25PT4523/25
Dead disc ceramic (2540) blown apart, 10r fusible resistor (3524) o/c and diode (6524) s/c. 2540 330pf 2kv disc ceramic (4822 126 11254) 7540 stp4na60fi fet (4822 130 63787) 3524 10r 0.33w 5% fusible resistor (4822 052 10109) 6524 byv10-20 diode (4822 130 31631)
PHILIPS MD1.2E
Width on right side varies in 14/9 mode Check on 16/9 panel the soldering of c2403.
PHILIPS MD1.2E
Vertical lines bended Check the connection of the eht cable inside lot.
PHILIPS MD1.2E
Vertical black bars in 14:9 mode Check soldering of c2403 on 16:9 pcb.
PHILIPS MD1.2E
Vertical amplitude of picture is too high Change item c2137 on the small signal panel to: 2.2uf (10v) capacitor 5322 126 14103
PHILIPS MD1.2E
Various faults (usually no picture). Suction pad of the ht cable turned inside out. check and replace if necessary (if defective): ic7119 - tda8366 - on ssp 4822 209 14927 ic7113 - tda8395 on ssp 4822 209 90129 t7366 on crt panel 5322 130 41982 t7420 on 16/9 pan
PHILIPS MD1.2E
Update styling 148 product survey Update styling 148 product survey item nr service code description 12 4822 320 12377 eht cable acef 4822 157 71539 degaussing coil 25" (not in drawing) bdg 4822 157 71529 degaussing coil 29" (not in drawing) set div
PHILIPS MD1.2E
The bottom left side of picture shows a green teletext symbol The bottom left side of picture shows a green teletext symbol whether or not the teletext is switched on. subtitling is selected, but the subtitling page is not stored. switch off the subtitle function by pressing the subtitle knob on the remote cont
PHILIPS MD1.2E
Survey of dfu service code numbers Survey of dfu service code numbers * only for sets with 60k up (tmp87pm38n) * set type languages brand service code number 4:3 & 16:9 fr-nl-du-it philips 4822 736 14982 4:3 & 16:9 fr-nl-
PHILIPS MD1.2E
Supply goes in protection during start-up Change item c2137 on the small signal panel to: 2.2uf (10v) capacitor 5322 126 14103
PHILIPS MD1.2E
Sound absent No 30v to sound o/p chip - ic7761 tda2626qn1 & 1572 2.5a wickman fuse off pin 13 chopper tfmr
PHILIPS MD1.2E
Sometimes no colour when set is switched on Check capacitor c2143 (100nf)
PHILIPS MD1.2E
Set up mode entering S/c the 2 pins centre of small sigs panel
PHILIPS MD1.2E
Set totally inoperative. supply is hickupping. Check d6423 in line circuit.
PHILIPS MD1.2E
Set totally inoperative. crackling sound out of set. supply hickuping Check l.o.t. pos 5430 and d6463/f1463/t7760
PHILIPS MD1.2E
Set total inoperative (no leds) Check and replace x1651 (crystal of up) on the ssp. code number: 4822 242 81946
PHILIPS MD1.2E
Set switches to hall audio mode by itself Only for sets with typenumber xxpxxx12 or xpxxx32 -------------------------------------------------- check in the service alignment mode if the micro controller version is: m12do1-1.0, m12do2-1.0, m12do1-1.1, m12do2-1.1, m12do1-1.3 or m12do2-1.3 in t