PHILIPS L6.1
Focus not optimal Check/replace lot l5422.
PHILIPS L6.1
Does not find all programs during search. Replace microprocessor ic7600 with version l6notxt-2.0, codenumber 4822 209 13085.
PHILIPS L6.1
Does not find all programs during search (for txt and no-txt versions) New software will solve this problem. change software into new version;codenumbers are still identical 4822 209 14646:txt 1 p mono pan-european l6txtmoeu-1.1 3/4 keys:saa5290zp/072 4822 209 15425:txt 1 p mono greek/turkisch l6tmogt-1.1
PHILIPS L6.1
Dead, loptr s/c Replace c2503 with 33nf 250v (532212142489), r3512 with 68k, d6510 with 12v zener
PHILIPS L6.1
Dead - chopper s/c, mains fuse o/c etc Fit repair kit - still dead with squealing from tfmr - pin hole in but11ax encapsulation (measured ok out of cct)
PHILIPS L6.1
Cross picture (you can partly see the picture of the next station) Add new saw filter (ce marking module = 4822 212 11352). this filter can be switched between bg and dk. how to adapt the set: * remove saw filter on position 1001 and replace by ce marking module. * solder the black wire in the hole mce1 near .p
PHILIPS L6.1
Cracks in sound during fast changing of picture from black to white. New solution: replace 9001 by 39Ω nfr = 4822 052 10399 and add 470 uf between 9001/3013 and ground (470 uf=4822 124 80791)
PHILIPS L6.1
Cracks in sound during fast changing of picture from black to white. Change c2425 to 2200uf 25v.codenumber 4822 124 42449. remarks : this only occurs if contrast is at maximum.
PHILIPS L6.1
Colour flashes appears or loss of chroma in secam standard Change r3433 (see diagram a1) from 39k to 56k service code 4822 051 20563
PHILIPS L6.1
Code-number supply-repair kit l6.1 Code-number supply-repair kit l6.1 ---------------------------------- in the service manual of the l6.1 the codenumber of the supply-repair kit is missing. the code-number is 4822 310 10663.
PHILIPS L6.1
Bending picture depending on its white contents. Change r3420 (see diagram a1) from 12k to 18k (service code 4822 116 52251) iris code : 1353
PHILIPS L6.1
Bad focus or focus varies in a new set or after crt replacement Possible solution: short circuit the focus and the g2 pins of the picture tube with the aquadag coating. switch the set on for approximately 5 seconds. after this return the set to its original condition. check if the focus adjusted normally. if not repla
PHILIPS L6.1
After a while white screen. Check/replace lot l5422.
PHILIPS L6 SERIES
Dead Chopper fet, sops kit & ht smoother c2515 47µ 200v
PHILIPS L2.2AA 29PT828C/05
Dead - 5a fuse in plug o/c Mains rect cap arcing 220µ 385v
PHILIPS L01.2EE 21PT4457/05
No red at sw on then reverts to st/by R3316 68r 1/2w o/c, tr7311 bf422 s/c b- e - on crt base
PHILIPS L01.1 28PT5107
1cm noise band from top to bottom lh side of screen varies with brightness & chan D6460 by 228 over loptx
PHILIPS L 6.2 / 6.3
Int locks up - no can change or switch on/off Replace 7505 (bc337-40 it is close to power transformer secondary side. (ref leif)
PHILIPS L 6.2
Bu1508ax has short life Orange cap in deflection pcb+ l 5420+.l 5421 in base-circuit
PHILIPS L 6.2
Horizontal line If +25 volt missing on 110 degr. module,then check d6907, this can be s/c ( use only byv 27-400) also check r3908 isn't touching spring for t7904 & check r3928 1r