Make Model Symptom Problem Solution By
PHILIPS GR1AX
Intermittent power supply - crowbar tripping R 3629 33k o/c which is in parallel to 3627 33k so either res could give you the same fault
PHILIPS GR1AX
Intermittent dead. Transistor 7521 base loose.(dry joint).
PHILIPS GR1AX
Intermittent colour also an occasional dark vertic Crack in print leading from pin 10 of lopt
PHILIPS GR1AX
Int trip at sw on ht correct at 100v Check d6638/6639/6640 zener diodes.
PHILIPS GR1AX
Int shut down Dry joint at scan coil plug
PHILIPS GR1AX
Int destruction of line tr Replace t7521 & t7523 ( bc337 )
PHILIPS GR1AX
Int dead with ht still present C2523 6µ8 line driver supply decoupler
PHILIPS GR1AX
Int crowbar trip R 3629 33k o/c which is in parallel to 3627 33k so either res could give you the same fault
PHILIPS GR1AX
Int buzz Cf1036 6mhz filter
PHILIPS GR1AX
Initial volume-level is higher than the maximum hotel-mode setting. * deactivate the hotel-mode. (the procedure is family depending). * switch-on the menu-volume control (via the rc for a 3 local- control set) and adjust the level till a normal low volume-level. * press the "store" buttom. now the personal preference le
PHILIPS GR1AX
Hotel mode switching in & out Sw off or on - chan 38 "store" & "chan +" together
PHILIPS GR1AX
Hotel mode for gr1ax with 8 local controls with uc Hotel mode for gr1ax with 8 local controls with uc tmp47c434n-3414 ------------------------------------------------------------------ replaced by uc tmp47c434n-r221; 4822 209 32192 hotel mode for uc tmp47c434n-3414: yes hotel mode activation
PHILIPS GR1AX
Hotel mode (de)activation for gr1ax with 3 local c Hotel mode (de)activation for gr1ax with 3 local controls --------------------------------------------------------- only for sets with 3 local controls in service information hotel mode for gr1ax / anubis a&b / tv/vcr-1 4822 727 20384 a mistake is made f
PHILIPS GR1AX
Hotel fashion Hotel mode ---------- control microprocessors are available for these chassis with or without the "hotel" mode feature. original production included "hotel" mode but the feature was deleted to reduce the number of "nuisance" service calls generated by mi
PHILIPS GR1AX
Half a pic - line wrap around Line sect of scastle pulse at r3529 missing to ic7020 tda8305 - crack in print at corner of pcb
PHILIPS GR1AX
H.t. varies sound goes up to max C2631 ( 22nf )
PHILIPS GR1AX
H.t. high Raa mistake (Aq)
PHILIPS GR1AX
Green picture Check t7435 (bf422; 4822 130 41782) on the crt panel.
PHILIPS GR1AX
Green pic with fb lines &/or no tuning/chan change Tmp47c434-3559 micro
PHILIPS GR1AX
Gr1ax with 8 local controls with uc tmp47c634n-r49 Gr1ax with 8 local controls with uc tmp47c634n-r494 (for sets with sv-codes) ------------------------------------------------------------------ 4822 209 31641 hotel mode for uc tmp47c634n-r494: yes hotel mode activation for uc tmp47c634n-r49