Search: philips
Results: 14210
Make Model Symptom Problem Solution By
PHILIPS GR1AX
Gr1ax with 8 local controls with uc tmp47c634n-r49 Gr1ax with 8 local controls with uc tmp47c634n-r494 (for sets with sv-codes) ------------------------------------------------------------------ 4822 209 31641 hotel mode for uc tmp47c634n-r494: yes hotel mode activation for uc tmp47c634n-r49
PHILIPS GR1AX
Gr1ax with 8 local controls with uc tmp47c434n-r22 Gr1ax with 8 local controls with uc tmp47c434n-r221 --------------------------------------------------- 4822 209 32192 hotel mode for uc tmp47c434n-r221: yes hotel mode activation for uc tmp47c434n-r221: 1. select program 38 2. press
PHILIPS GR1AX
Gr1ax with 8 local controls with uc tmp47c434n-353 Gr1ax with 8 local controls with uc tmp47c434n-3537 --------------------------------------------------- replaced by uc tmp47c434n-r221; 4822 209 32192 hotel mode for uc tmp47c434n-3537: no
PHILIPS GR1AX
Gr1ax with 8 local controls with uc tmp47c434n-341 Gr1ax with 8 local controls with uc tmp47c434n-3415 --------------------------------------------------- replaced by uc tmp47c434n-r221; 4822 209 32192 hotel mode for uc tmp47c434n-3415: yes hotel mode activation for uc tmp47c434n-3415: 1.
PHILIPS GR1AX
Gr1ax with 3 local controls with uc tmp47c434n-314 Gr1ax with 3 local controls with uc tmp47c434n-3141 --------------------------------------------------- replaced by uc tmp47c434n-3142; 4822 209 32118 hotel mode for uc tmp47c434n-3141: no
PHILIPS GR1AX
Gr1ax with 3 local controls with uc tmp47c434n-314 Gr1ax with 3 local controls with uc tmp47c434n-3142 --------------------------------------------------- 4822 209 32118 hotel mode for uc tmp47c434n-3142: yes hotel mode activation for uc tmp47c434n-3142: 1. select program 38 2. press
PHILIPS GR1AX
Field non lin with line thro centre R3506 13k or 43k hi res
PHILIPS GR1AX
Field collapse usually with blank screen Yashkh000
PHILIPS GR1AX
Field collapse Replace field chip
PHILIPS GR1AX
Faulty functions with remote control rc 5701. Battery spring does not contact philips alkale battery. change remote control. remarks : the spring has been changed in production from week 9212 onwards.
PHILIPS GR1AX
Faulty functions with remote control rc 5701. Battery spring does not contact philips alkale battery. change remote control. remarks : the spring has been changed in production from week 9212 onwards.
PHILIPS GR1AX
Failures in the power supply In the event of a failure in either r3616, r3680, r3614, mosfet 7610 or d6610, it is recommended that all four components should be replaced. during fault finding do not connect any probe to the gate of the mosfet 7610 to measure voltages and waveforms a
PHILIPS GR1AX
Fails to stop at station when tuning L5045 o/c
PHILIPS GR1AX
Excessive height , lin faulty , field blanking C2043 82pf
PHILIPS GR1AX
Excess non lin height & part pic blanked - int C2043 82pf int
PHILIPS GR1AX
During picture changes sometimes a volume increase (plop) is heard. Replace bridge-wire (/jumper) 9511 by diode 6031 bzx79-c12, (4822 130 34197), section/location f7, page 8, of chassis gr1-ax 20" (4822 727 18093). add diode 6032 bzx79-c12, (4822 130 34197), section/location g7 of the chassis lay-out. note
PHILIPS GR1AX
Dim picture lines on colour D6326 12v zener
PHILIPS GR1AX
Dim pic with hanover bars - no sndcl pulses D6326 bzx79c12 s/c
PHILIPS GR1AX
Dead. D6610 ( bzx79c10 ) zener.
PHILIPS GR1AX
Dead with st/by light flashing - psu ok No line drive or start up volts pin 16 tda2579 timebase gen - r3455 1k safety feed res high res