PHILIPS G8
Raster - bright raster & flyback lines. R5576 ( 4r7 ) o/c on scan panel.
PHILIPS G8
Power supply flutter - intermittent. C216.
PHILIPS G8
No colour R3215 ( 1.8m ) o/c.
PHILIPS G8
No colour Filter network u3008 ( 220pf ) leaky.
PHILIPS G8
Hum bar. Extend mains lead by about 1 foot!
PHILIPS G8
Ht control will not adjust to 205v R1365 47k high.
PHILIPS G8
Frame cramping at top. D4443 ( oa47 ) leaky , r4441 high.
PHILIPS G8
Frame - picture jitter. C5536 ( 600u f ) o/c on 205v rail.
PHILIPS G8
Frame - black band at top of picture. C22 , c51 , c55 , l120 , r49.
PHILIPS G8
Flyback - lines at top. C216.
PHILIPS G8
East west. Loptx
PHILIPS G8
Dead. Earth print on if strip blown.
PHILIPS G8
Dead - blowing 250ma fuse intermittent. Check for flash over on r414 to r212.
PHILIPS G8
Dead - after 15 mins. Fuse 800ma.
PHILIPS G8
Dark picture. 12v zener in beam lim cct , poor connection on plug j ltb.
PHILIPS G8
Colour - hanover bars. Drys on loptx.
PHILIPS G111S 25GR6771/56R
Lines at top of screen 10cm down screen Sm resistor 3807 (150r)
PHILIPS G111 25GR6771/79
Dead, no st/by led Replace 2sc3975b (wont oscillate ) in primary of power supply
PHILIPS G110-S
Set dead; during switch-on, led momentarily on with amber light. Two possible solutions: 1. replace up ic7200 by tmp47c634n-r364 (4822 209 31492) and keyboard pos 1210 by 4822 218 21032 2. upon switching on, if the set is hung, do the following initialising for the up - switch off the set. disconnect pin 41 of up
PHILIPS G110-S
Picture jumping when switching from pal to ntsc m Place on copper side across item 2503 +ve to +ve and -ve to -ve of item 2503 a capacitor of 1uh 20% 50v (4822 124 40242). remarks: introduced in production in week 9252