PHILIPS FL1.1S
Coloured spot on screen during switch-off As service solution the eht cable can be replaced by 4822 218 21041 this is a eht cable with bleeder to provide a faster discharge time. remarks : only implement this service solution when it is necessary. please note that a colour spot, which
PHILIPS FL1.1S
Colored picture or picture is green/red, fly-back lines Check zenerdiode 6450 on pin 19-ic7430 on the lsp. new diode must be philips (telefunken does not work), 4822 130 81512
PHILIPS FL1.1S
Bux85f in mikrosops defective Change the value of c2260 to 4n7f, replace 7270 with transistor bd825 (4822 130 41746).
PHILIPS FL1.1S
Bad or no functioning of the tda4680/v4. Check/replace ic7430 tda4680/v4 (4822 209 31592). it is recommended to add a zener diode bzx79-c12 (4822 130 34197) between pin 28 of the tda4680/v4 and anode to ground. remarks : introduced in production in week 9140.
PHILIPS FL1.1S
Bad focus or focus varies in a new set or after crt replacement Possible solution: short circuit the focus and the g2 pins of the picture tube with the aquadag coating. switch the set on for approximately 5 seconds. after this return the set to its original condition. check if the focus adjusted normally. if not repla
PHILIPS FL1.1S
50hz buzz noticable through speaker Check/replace ic7680 on the ssp - tda8425, pseudo stereo ic. (4822 209 63734).
PHILIPS FL1.1AA
Width int reduces with no e-w corr Crack in print between r3608 & r3607
PHILIPS FL1.1AA
To over-ride prot cct Short pins s24 & s25 momentarily
PHILIPS FL1.1AA
Reverts to st/by & prot mode at sw on Dry joint l5521 or c2504 blue disc ceramic cap leaky or lack of por signal due to o/c in track from tr7272 coll to small signal panel jumper
PHILIPS FL1.1AA
Line prot cct operating Crack in print near scan coils plug
PHILIPS FL1.1AA
Int shutdown ( lights flashing ) D6373 ( 18v zener )
PHILIPS FL1.1AA
Int goes into prot mode - st/by, mute & stereo leds flashing D6376 18v zener sm
PHILIPS FL1.1AA
Chirps at sw on then goes into prot mode Transistors 7542 & 7540 in e-w cct s/c
PHILIPS FL1.17
Wrong synchronization, unstable colors D6417 on the lsp dependent on temperature, check/replace (4822 130 81223)
PHILIPS FL1.17
Wrong service batch of st24c08cb1 memory ic's Wrong service batch of st24c08cb1 memory ic's 4822 209 32283 ------------------------------------------------------------ temporarily a wrong batch of earom's has been delivered, causing the fault "nvm memory not write protected" after replacing the earom
PHILIPS FL1.17
Wrong options/no options in memory; several functions do not work. Re-adjust the options and implement the iic-bus protection (mc33164). see service information fl1 93.02
PHILIPS FL1.17
Vertical shift is difficult to adjust. It is recommended to add r3471 (2k2; 4822 041 20222) remarks : introduced in production in week 9337.
PHILIPS FL1.17
Various faults can be observed. Check the earth connection from the ssp: connect earth tuner with earth line output transformer (lsp) to find-out whether the problem is solved. check connectors l02 and s02 pins 1,2 (sometimes only 7 wires are used in the connector)
PHILIPS FL1.17
Unstable picture, horizontal jitter. Check/replace r3405 on the lsp. (4822 051 10303 for 50 hz sets; 4822 051 10333 for 100 hz sets).
PHILIPS FL1.17
Tuning does not function Resistor r3240 on lsp in v-tuning wire broken.