PHILIPS |
3A
|
+ 140 v not present | Replace ts7687 (but12a; 4822 130 43919) also exchange ts7674 (bc337; 4822 130 40855) ts7685 (bc547; 4822 130 44257) ts7686 (bc369; 5322 130 44593) | ||
PHILIPS |
37TVB10/39N
|
Codenumber information | A new software version (ptcp2-7) is available for the control up (ic 7801). service codenumber is 4822 209 15271. this new version is only used in the following sets: 14pv263/01, 14pv162/01, 14pv162/05, 14pv162/07, 14pv163/05, 14pv163/05h, 14pv263/01 | ||
PHILIPS |
37TVB10
|
Key set | The key set assy has been codified for all b-range tvcr's. this will allow to change the keys without having to change the complete frame. servicenr.: 4822 410 11076. key set for: 37tr120/01/08 - 37tr126/03/38 - 37tr125/38n - 37tvb10/39n. | ||
PHILIPS |
37TR126/38
|
Codenumber information | A new software version (ptcp2-7) is available for the control up (ic 7801). service codenumber is 4822 209 15271. this new version is only used in the following sets: 14pv263/01, 14pv162/01, 14pv162/05, 14pv162/07, 14pv163/05, 14pv163/05h, 14pv263/01 | ||
PHILIPS |
37TR126/03
|
Option code: 00398 | From week 02/97 onwards the option code is printed on the typesticker. always use this code ! for early sets without this information on the typesticker, the option code is: 00398. | ||
PHILIPS |
37TR126/03
|
Codenumber information | A new software version (ptcp2-7) is available for the control up (ic 7801). service codenumber is 4822 209 15271. this new version is only used in the following sets: 14pv263/01, 14pv162/01, 14pv162/05, 14pv162/07, 14pv163/05, 14pv163/05h, 14pv263/01 | ||
PHILIPS |
37TR126
|
Start up problems after replacing ts7352 | When ts7352 is replaced, it can happen that the set doesn't start up properly. there are 2 possible solutions for this problem: - use sgs type mtp3055e (4822 130 63726). - in case of a motorola type mtp3055v (4822 130 60838), add a 22 uh coil solde | ||
PHILIPS |
37TR126
|
Start up problems | When the set is switched on by the mains-switch while a cassette is in the set, the front led starts blinking, but the set doesn't start. solution: check the primary voltage (ubat) and adjust this for 14" sets to exactly 101.5 volt. (see chapter 3.1.1 of | ||
PHILIPS |
37TR126
|
Spare part information | If the lever inside the mains-switch is broken, the switch doesn't remain in the "on" position. solution: replace the switch by a new one. improved switches of a newer production range are on stock. (4822 276 13542) | ||
PHILIPS |
37TR126
|
Set produces audible noise in stand-by | Add a small lebl (leading edge blanking) pcb, to avoid auto oscillation of transformer 5330 (or 5331). a modification letter is included with the lebl pcb. this pcb is available with service nr. 4822 214 12173. | ||
PHILIPS |
37TR126
|
Set produces audible noise in stand-by | Add a small lebl (leading edge blanking) pcb, to avoid auto oscillation of transformer 5330 (or 5331). a modification letter is included with the lable pcb. this pcb is available with service nr. 4822 214 12173. since production week 9723 this circuit is | ||
PHILIPS |
37TR126
|
Preventive tip | If fet 7352 is found to be defective, it is advised to mount a 15 v zenerdiode (bzx79-c15) between the drain and the gate. mount cathode to gate and anode to drain. codenumbers: fet 7352: 4822 130 60838 zener (bzx79-c15): 4822 13034281 | ||
PHILIPS |
37TR126
|
Key set | The key set assy has been codified for all b-range tvcr's. this will allow to change the keys without having to change the complete frame. servicenr. 4822 410 11076. key set for: 37tr120/01/08 - 37tr126/03/38 - 37tr125/38n - 37tvb10/39n. | ||
PHILIPS |
37TR126
|
Codenumber information | Please add following codenumbers to the service manual: lift-flap 37tr126/03 : 4822 443 10413 spring for lift-flap : 4822 492 70896 | ||
PHILIPS |
37TR126
|
Codenumber information | The codenumber for the spacer between on/off switch and the knob (pos 3) is 4822 402 10702. | ||
PHILIPS |
37TR126
|
Codenumber correction for deck-up (ic7410) | The codenumber for the deckprocessor was wrong in the first service manual (4822 726 15451). in service information tvcr96-01 and in the new manual the correct codenumber is given. the codenumber for the deck-up for sets with non-turbo drive is: 4822 | ||
PHILIPS |
37TR126
|
Codenumber correction | The codenumber of pos. 1701 (tuner) for 14 inch sets with iec input is 4822 210 10691 (uv916s). | ||
PHILIPS |
37TR125/38
|
Codenumber information | A new software version (ptcp2-7) is available for the control up (ic 7801). service codenumber is 4822 209 15271. this new version is only used in the following sets: 14pv263/01, 14pv162/01, 14pv162/05, 14pv162/07, 14pv163/05, 14pv163/05h, 14pv263/01 | ||
PHILIPS |
37TR125
|
Key set | The key set assy has been codified for all b-range tvcr's. this will allow to change the keys without having to change the complete frame. servicenr. 4822 410 11076. key set for: 37tr120/01/08 - 37tr126/03/38 - 37tr125/38n - 37tvb10/39n. | ||
PHILIPS |
37TR120
|
Key set | The key set assy has been codified for all b-range tvcr's. this will allow to change the keys without having to change the complete frame. servicenr. 4822 410 11076. key set for: 37tr120/01/08 - 37tr126/03/38 - 37tr125/38n - 37tvb10/39n. |