PHILIPS HL3254
It doesn't work (it stays off). Check that the 2k wire resistor is not open, see also 1n4142 diode with leakage (12v). * Dec 94 BC *.
PHILIPS HL3254
Pulse function does not work Function key with oxidation. * Dec 94 anac *.
PHILIPS GR6-LS
Vertical deformed compressed parts C2226 (pin 51 bimos) causes compression of the lower part of the screen. *03Sep98 sp224*
PHILIPS GR6-LS
Green fabric Check integrated 7051. * 21ago97 ctr *.
PHILIPS GR6-LS
Dark "black" screen (see also bril4). R3585, 3586. *01Sep98 mg608* dark screen with retrace lines. check and or repro list the addresses that are probably changed. *03Sep98 spe188*
PHILIPS GR6-LS
Gray screen (no video) R3060 (tube plate) open. *03Sep98 h.desk* without luminance and with retrace lines, check ic7273 (tda4662). *17Sep98 CP160*
PHILIPS GR6-LS
White screen, without retractions. R3060 (22e), white screen when turned on and then the device turns off. *08Sep98 sp534*
PHILIPS GR6-LS
Blue fabric Check integrated 7053. * 21ago97 ctr *.
PHILIPS GR6-LS
So fica em stand by (power off). 1262 (bimos crystal). *03Sep98 sp224*
PHILIPS GR6-LS
No sound. (with or without image for TV, VCR). Corrupted eeprom causes loss of sound. *01Sep98 mg399* c2807 (pin 7 stereo decoder) causes loss of one of the channels. *03Sep98 sp224*
PHILIPS GR6-LS
No tuning bass channels. Possible defective tuning unit (u1290). * 21Aug97 jpba *.
PHILIPS GR6-LS
Without horizontal synchronization. C2503. *05nov98 h.desk*
PHILIPS GR6-LS
Noise not som T7230 (pin 7 bimos). *03Sep98 sp224* c2755 no capacity. *08Sep98 df102*
PHILIPS GR6-LS
Remote "locator" does not work. Change in bank1 f9 from ff to f7. * 16oct97 jpba *.
PHILIPS GR6-LS
Intermittently loses tune or (loop). If the device is ok on another system (PAN/NTSC), check comb filter panel, possibility of defect in the regulator 5v. * 21Aug97 jpba *. check programming table (change bank 00 to bank 01) and check addresses: f8=a9, f9=b7 (2
PHILIPS GR6-LS
It doesn't work (it stays off). Check possible short in tsh 5503. * 15set97 ctr * check sops trafo (pin 8 with broken track). * 16oct97 jpba *. check transistor 7502 (broken terminal). * 16Oct97 jpba *. r3422 or r3423 *01Sep98 mg6
PHILIPS GR6-LS
Does not open vertically Capacitors soldered to the eeprom (filter) terminals has caused the upper part of the screen to go dark. *03Sep98 sp224*
PHILIPS GR6-LS
Factory service mode. If fa, fb, ... appears in place of sa, sb, ..., press vol and can+ simultaneously to exit. * 16oct97 jpba *.
PHILIPS GR6-LS
Return lines (retraction). R3060 (22r). *18set98 cp160*
PHILIPS GR6-LS
LED(s) flashing. (repeatedly) Five times, check possible short in tsh 5503. * 15Sep97 ctr *. six times, check diode 6505 for short, see also tsh 5503. * 15Sep97 jpba . check transistor 7502 (broken terminal). * 16Oct97 jpba *. r3537 (2k7) open.