Samsung Repair Tips
Search: samsung
Results: 3847
Results: 3847
Make | Model | Symptom | Problem | Solution | By |
---|---|---|---|---|---|
SAMSUNG |
SYNCMASTER 15GE, 15GLE, 4NE
|
Vertical distortion | Check c306, c308, c310, c312 | ||
SAMSUNG |
SYNCMASTER 15GE, 15GLE, 4NE
|
Inoperative panel controls | Check ic201 | ||
SAMSUNG |
SYNCMASTER 15GE, 15GLE, 4NE
|
Contrast control inoperative | Check q173, q172, d174, q181, q182, ic101 | ||
SAMSUNG |
SYNCMASTER 3NE
|
No image | D505 | ||
SAMSUNG |
SYNCMASTER 3NE
|
Insufficient width | C422 (2,8 nf 1,6 kv) | ||
SAMSUNG |
CVM4967T
|
Shaky image | C302 (0,68 µf 35 v) | ||
SAMSUNG |
CVM4967P
|
Dead, burning horizontal output transistor | Flyback and horizontal output transistor | ||
SAMSUNG |
CVM4967P
|
Image at the bottom of the screen | Vertical outlet IC (LA7838) | ||
SAMSUNG |
CVM4967
|
No cushion adjustment | C207 | ||
SAMSUNG |
CVM4967
|
Dead | Flyback | ||
SAMSUNG |
CVM496*P E CVM478*P
|
Image scrolls up/down | Check Q301, Q302, D303-D305, C308, IC301. adjust vr304 | ||
SAMSUNG |
CLV495
|
No high voltage | Verificar t402, r434, q402, c421, c423, d406, d409, d410 | ||
SAMSUNG |
CLV495
|
No width adjustment | Check q403, q404, c425 | ||
SAMSUNG |
CLV495
|
Contrast adjustment inoperative | Check q187, r198, vr191, q186, c189, d190 | ||
SAMSUNG |
CLV495
|
Brightness adjustment inoperative in vr501 | Check vr501, vr101, r507, q501, d501, d502, c501, c503, r501 | ||
SAMSUNG |
CLV495
|
Does not turn on, fuse f601 ok | Check r602, r603, r604, d606, ic601, r606, c616, vr601, d607 | ||
SAMSUNG |
CLV495
|
Does not turn on, fuse f601 open | Check d601-d604, c613, ic601 | ||
SAMSUNG |
CLV495
|
Vertical line | Check c423, c424 | ||
SAMSUNG |
CLV495
|
Horizontal line | Check ic301 | ||
SAMSUNG |
CLV495
|
Bad image at top and bottom | Verificar c311, c322, c309, c310, c313 |