Make Model Symptom Problem Solution By
SHARP 66FW-53H DA100
Dead - loptr s/c, c720 100µ 200v split open Opto-coupler (ic705) and the two damaged components above (q601 & c720). fit avalanche diode across c720 to prevent future damage (cathode to positive). a new tea5101a (ic1801) was also fitted on the crt panel as a precaution
SHARP 66FW53H DA100
Dead Ic 705 rh-fx0110bmzz, cny17f-2; c720 rc -ez0258cezz, 100uf 200v; d735 rh-ex0875bmzz diode avalanche; d712 rh ex0419bmzz, diode15 zener; q701 rh-tx0198bmzz s5410n80a ; q702 rh-tx0182bmzz 2pd602ar[s.m.]; q703 rh-tx0151bmzz 2sd2391q [s.m.]
SHARP 66FW53H DA100
Constant trip Bypassing prot (s/c pin 15 ic702 to chassis) brought pic on with limited functions - sm nvrom chip faulty & adj geometry settings (maunual reqd)
SHARP 66FW53H
St/by only D735 (rh-ex0875bmzz), ic705 cny17f-2 (rh fx0110bmzz, c720 100µ 200v - use heat sparingly when fitting new opto
SHARP 66FW53H
St/by only R714 560k start up res - also check r713 560k
SHARP 66FW53H
Rotated pic (not horizontal) Replaced the following in rotation control cct on crt base - ic1601 vhiba4558f/-1 (ba4558 ic), q1603 vs2sc2412kq-1 (2sc2412 trans), q1604 vs2sa1037kq-1 (2sa1037 trans)
SHARP 66FW53H
Loptr repeated failure Loptx faulty
SHARP 66FW53H
Dead with bang C720 blown, r765 & 766 100r sm o/c, r623 1r o/c & q601 buh515 s/c, caused by opto ic501 moc8106
SHARP 66ES03H
Service mode entering Vol down & channel up at switch on - go to st/by to store
SHARP 66ES03
Field collapse F601,f602,q501,q502
SHARP 66ES03
Dead still, after psu & lop stage rebuild C607 330µ in psu sec & check other caps in the region
SHARP 66DS-03H CA10
Dead - psu blown up due to faulty opto coupler Replace q702, 703 etc & opto - careful not to overheat it when soldering new one in or hi ht persists see sharp tech bulletin ctv20010101
SHARP 66DS03H
Field collapse then dead C613 dry joints
SHARP 66CSD8H
Service mode entering Press ch+ and vol- and switch on
SHARP 66CS05
No sound/pic but dull raster with purity type errors R631 (not a resistor but a fuse)- d623 10v zener sm & r643 5r6
SHARP 66CS05
Long time to come on C714 1000m
SHARP 66CS05
Field top cramp when cold C517 22m
SHARP 66CS-03H
Slow start up from cold - leds flash gn/or Check dry joints & c714 1000µ 25v d712 reservoir cap
SHARP 66CS03H
St/by only Ripple on 5v supply caused by c714 1000µ 10v low cap
SHARP 66CS03H
Slow start from cold Replace c714 1000mfd10v