Search: sharp
Results: 1784
Make Model Symptom Problem Solution By
SHARP 4BSC DV6632H
Very faint colour lines on the top C501 vceaga1hw107m, c506 vceaga1vw107m leaky
SHARP 4BSC DV6632H
Repeated failure of loptr Resolder scan coil connections
SHARP 4BSC DV6632H
Line pulling, bent verticals C623 4.7uf 50v next to q603 regulator
SHARP 4BSC DV6632H
Frame foldover at the top C505 100uf 40v
SHARP 4BSC DV6632H
Burst of eht then shuts down Ic500 tda8170 s/c r645 1r 1w o/c
SHARP 4BSC DV5940H
Stuck in stby D600 1n4936 s/c, r645 1r 1w o/c on loptx pin 3
SHARP 4BSC DV5940H
Dead, loptr s/c Q600 2sd1546 s/c, smd q606 2sc2412 leaky, resolder scan coil plug
SHARP 4BSC 66AS05H
Stuck in stby, when brought out led goes green, quick burst of eht, then shuts down with led red Smd q606 2sc2412 leaky
SHARP 4BSC 66AS05H
No line aft repairing dry joints scan coil & loptr s/c leds sw between red/green Leaky s.m. transistor q606 [2sc2412] in the line drive circuit.
SHARP 4BSC 66AS05H
No e-w corr aft replacing tda8170 fop chip, r645 & c506 for tripping off Q603 2sd1913s collector base leakage, and c603 4.7uf high esr
SHARP 4BSC 66AS05H
Excessive width with e-w error L601 shorted turns (rcilp0104cezz)
SHARP 4BSC 66AS05H
Dead with ticking Loptr s/c due to dry joints scan coil plug
SHARP 4BSC 66AS05H
Dead - no line drive Ic800 mc44002 jungle chip faulty
SHARP 4BSC 66AS05H
Dead - loptr 2sd1546 failed Replacement only lasted days - ic800 mc44002p line drive pin 12 only 1v instead of 3v - chip faulty. also check state of q601 2sc2271 dr tr & q606 pre driver tr
SHARP 4BSC 66AS05H
Dead Lop tr q600 2sd1546 u/s. line drive wfm at c607 cramped - q606 2sc2412 sm leaky
SHARP 4BSC 66AS05H
Blank raster, osd ok Smd q400 2sc2412/bc848 s/c (video buffer transistor)
SHARP 4BSC
Trips int with burning smell - brief field coll noticed Ic500 fop chip burnt, c506 100µ 25v faulty
SHARP 4BSC
Eht dies away at sw on R465 1r o/c supply to field chip usually - 12v reg this time
SHARP 4BSC
Dead after initial ht supply rise Ic600 forms part of trip cct. r645 1r 1w safety res o/c
SHARP 4BS-B
Lop tr blown replacement overheats Line drive incorrect. 5v supply at ic2801 low - ic751 ka7805pi faulty