Make Model Symptom Problem Solution By
SONY XR77
No loading Cass will not load. this happens on models xr-50, xr-70.and xr-77. 385 deforms with use (years) to the point where loading isincomplete. 387 joint lever assy can latch 386 threading arm assy. removecass holder, then carefully bend upwards to restore 9
SONY ESR10
Wrong part number Reference numbers 229 and 230 are crossed. in orderingreverse pinch roller (item 230 on page 26 of service manual), i receivedforward pinch roller (item 229). -hq comments: we will issue a s/b.
SONY KPR4110
Cp6001 open, replaced cp6001 This unit is used with a panasonic vcr pv-1770 and when thevcr comes out of the scan mode (review) the unit will go into hv shutdownand sometimes open cp-6001. this is caused by a problem with the vcrchanging the horizontal freq. this unit opened cp-60
SONY SL5200
Int. blows f001 and q002 Unit would very int. blow q002 and f001. it was very hard tolocate the problem because short would disappear on the 12v line before itcould be located.
SONY SLHFR90
Servo adjustments in manual incorrect Test point for betascan drum speed adjustment (p. 202) isincorrect. also, x-0 jitter adjustment is impossible - can -hq comments: correct test point for betascan adjustment is ic021 pin 5.x-o jitter adjustment is not necessary due to servo improvement
SONY CDP70
Display indicates all zeros Display would not function, all zeros displayed at alltimes. all other functions were ok. inspection revealed no clock pulseson pin 37, ic106.
SONY CDP203
Rf pll alignment correction Service manual says to adjust l201 for 4.3218 mhz. i believethis to be in error and l201 should be adjusted for 4.2818 mhz. -hq comments: you are correct. i will issue a s/b.
SONY EVC8U
No video pb 1) unit had no playback video - just intermittent flashes.2) poor sync and rainbow in picture.
SONY SL5200
Color beat during playback with audio in connected Color beat on monitor only during p/b when audio input isconnected (e-e is ok).
SONY EVS700U
Video drop-outs after repeated playback Customer complaint: after repeated playback of a section oftape, dropouts develop. 1/4 inch diagnal scratches found near center oftape. not sure if problem develops during cue/rev or pause. unable toduplicate scratch at ssc.
SONY CFS700
Wrong part # in s/m Customer says part supplies does not match part in unit. seeletter from customer. -hq comments: the correct p/n for the spring is 4-854-771-00. a s/b wasissued - tape recorder #204.
SONY AIR8
Screw part # Customer has ordered part twice, and insists that it does notfit. part # on part matches that in s/m. is it possible that there is atypo in s/m? have tried to verify but do not have this model in shop. -hq comments: steve, i checked with kcp. last s
SONY WM75
No p/n - packing material, headphone jack No p/n for rubber packing which goes in the headphone jacks. -hq comments: p/n is 3-326-140-01. we will issue a s/b.
SONY CFS950
No p/n - rubber gasket No part number for rubber gasket that fits into (cabinet assy,front) ref #28. -hq comments: this item does not come separately. you must order thecabinet. we have asked tokyo to provide it in the future.
SONY CDXR7
Noise from unit when powered on When unit is powered on with disc off (tuner on, disc in orout of unit) noise is emitted from optical pick-up. noise is generatedfrom stator board. turning spindle by hand increases/decreases level.moving the disc table up or down on the shaft increase
SONY SLHF900
Fm modulator deviation adjustment Rv207 had to be replaced. deviation alignment on page 274requires a spectrum analyzer.
SONY SLHFR70
Interference Interference when vcr off and tv on active channel 3 (2 and 4not affected). interference rolls through picture, flashes when clockflashes on vcr display. scope shows interference on pins 14 and 15 of ic1power supply. problem appears only 5-10 min. aft
SONY KV2680R
Low audio, replace vol buffer q-1126 on x board The unit had very low audio on all functions. we found theproblem to be caused by a defective volume buffer/q1126.
SONY SL20
Scanning would not stop on channel In channel up or down mode, scanning would not stop onchannel. scanning continued to end of range. h sync pulse to systemcontrol ok.
SONY WMF75
Intermittent auto reverse Spurious auto reverse. the shut-off lever (b) was sticking.