Make Model Symptom Problem Solution By
SONY CCDV8AFU
No recording Unit playback was fine. would not record anything at all.snow was all that was on tape. all necessary signals were present,video, sync, record correct. would erase previous information.
SONY CDP650ESD
Alignment After installing bu-1c, alignment difficult to perform forrf pll.
SONY XR780
Am/fm tuner lock-up When advancing tuning manually, tuner would advance approx.2/3 of the way up the band normally, after which point the display wouldcontinue to advance, but actual station tuning would not. in scan mode,tuner would advance 2/3 of the way up the band, aft
SONY XR66
Schematic error - power pcb Seems radio would not turn off when ignition switch is off.found power pcb not etched properly causing continuity between yellowlead (back-up) and red lead (acc).
SONY M80
Rec/play "u" spring Need p/n for u spring that operates r/p sw.
SONY KV25DXR
Hmh not locked Home management helper program was out of sync. looked likea lot of dashed lines.
SONY CCDV8AFU
Intermittent break-up in picture/speed change sp/lp Record ok. during playback any tape including self-recordedpicture would break-up with white streaks and speed would change back andforth between sp/lp modes. troubleshooted atf circuit to no avail.changed ui-6 board with known good board, same thing.
SONY KPR4110
Intermittent picture, replaced ic-6006 This unit had intermittent muted video (no raster) whentapping on ic6006 or ic6008. the picture would flash to black.
SONY KV1981R
No display, open l101 Unit had no on screen display. found l101 open.
SONY CCDV8AFU
Breaks tapes on eject The unit breaks or streaks the tape on eject. we found theproblem to be caused by guide number 8. the guide was severely pinchingthe tape. this of course lead to excessive take up torque. surprisinglythe unit worked fine in pb and rec. readjustment
SONY KV2647R
Poor color, b and g wires to c board reversed The unit had fairly good b/w but the color picture definitelyindicated that there was some sort of demodulator problem. it was notpossible to obtain the correct color bar display - no yellow or magentaand the red, blue and green were misplaced. the ser
SONY SLHF900
Unit intermittently changes channel indication Intermittently the channel indication on the display tubewould change. eg. if channel 11 was tuned in, intermittently the displaywould read 123 and then change back to 11. there was no change in videoor audio information. we found the rqst, data and c
SONY FD40A
Absence of video, rotated yoke Complaint was absence of video, raster was ok. please notethat if anyone has replaced the picture tube on these units and acci-dentally installed the yoke 180 degrees out of position, the receiver willnot produce video.
SONY KV25XBR
No raster - no remote control function - sleep light on No raster - no remote control function - sleep light on.first checked for raster by turning screen control up, raster was visible,checked voltages at a-13 5v was low, checked q251 ok checked q251 leaky.
SONY KV2782R
Vertical lines and video collapsed, replaced yoke At turn on a 2 wide bar appeared on the screen with verticalretrace lines. scoped pin 2 of ic501 on d board the vertical pulse had alot of noise and pin 5 read 6v. checked all components in the area andused freeze spray unit ok for about 5 min. traced
SONY CDXR7
Replacement of display drive pc board ass Several cdx-r7s with cracked etchings on the display drivepcb assys. particularly right at the solder connections to the display(front panel) pcb. the face plate cannot be removed more than once or theflex cable breaks due to the angle at which it must
SONY SLHFR90
Shut down in play mode Unit would shut down intermittently in play, ff and rew ok.
SONY SLHF900
Tape damage from capstan overrun Unit would intermittently eat tapes after on index search ofcue/review. capstan motor would overrun and spill tape. observed amomentary low on pin 3 of ic505 (pwm gen) on ss-53 board would causecapstan motor to overspeed. this would continue even if t
SONY SLHF450
Adjustment method is incorrect Adjustment method in manual is incorrect, regarding forwardtorque, p176, section 3-14. the correct version may be found in thesl-hft7 manual. sl-hf450 manual lists wrong connector and pin numbers. -hq comments: we will issue a supplement on this matte
SONY BMC220
Black lines in picture Two diagonal lines black in picture during playback of self-recorded tapes. unit connected to monitor via bmc-j88u jig for testing.