Make | Model | Symptom | Problem | Solution | By |
---|---|---|---|---|---|
SONY |
CCDV8AFU
|
No playback/no record | Was unable to get unit to record, playback or erase. checkedheads with sl-5151 head checker. all checked ok. checked record andplayback amps, worked fine. | ||
SONY |
CDXR7
|
Noise before selection is played when using ams | A brief blip of sound is heard immediately before a selec-tion, accessed with an ams key, is played. this also occurs occasionallyduring the initial play of a disc. | ||
SONY |
SLHFR70
|
Malfunction of reel motor and system control | Found f002 in p.s. section open. after replacement, ic401 onsa-10 board gets very hot. erratic reel motor operation. f002 gets openagain. also, found d210 (sa-10 board) open. gets hot after replacement,the other problems still exists intermittently. | ||
SONY |
CDP70
|
Intermittent skipping | Unit would skip tracks intermittently at random. tracedproblem to cold solder on m701 minus terminal. have seen several unitswith either + or - terminals cold soldered. since motor is assembled intoboard, this could be a problem on similar models also | ||
SONY |
CDP7F
|
No focus search | The unit would not focus search. | ||
SONY |
KV1952RS
|
Unit shuts down, replace d502 | This unit would immediately shut down. we defeated the shut-down circuit by shorting the line from the hvr. then running the unit upon a variac we found ic501/pin 9 to be only 3.4v. the cause was a defec-tive d502. | ||
SONY |
KV1354R
|
Unit would not tune, replacedic-003 | The unit would not tune in the stations. it was not possibleto change the output of ic001/pin 12 pwm out. the problem was caused by adefective pll controller/ic003. interestingly, the upc seemed to work inall other respects - display, etc. | ||
SONY |
CCDV110
|
S/m page 20 what is natrium lamps? | Page 20 list natrium lamps under difficult conditions for linear auto w.b. -hq comments: natrium is the same as sodium vapor lamps. | ||
SONY |
TCD5
|
Part not available - pause spring | Part is on national back order. pls assist in locating part. -hq comments: there are none in the usa. hopefully rpc (tokyo parts)will have some. since this is an older unit though, they may not. | ||
SONY |
KV25DXR
|
Dark picture - no color sync | Set had very dark picture and no color sync. | ||
SONY |
TAV5
|
Unit dead - no power | Unit was inoperative due to malfunction of power supply.static tests revealed q901 base to collector short, r901 open and bothdiodes in ib901 circuit block were shorted. | ||
SONY |
KV1500
|
White dots across top of screen | White dots across top of picture, looks like unblacked vitssignal. vert. height and lin. controls have correct range. | ||
SONY |
KV25DXR
|
Bar in middle of picture, replaced ic502 afc control | Ghost image overlays normal video on screen. horizontalblanking bar appears in middle of pix. | ||
SONY |
CDP302
|
Intermittent skipping | Unit would play normally for a time then start to skip. afterwarmup it would occasionally fail to read toc. i noticed that the efbalance drifted after warmup and that freezing the rf amp ic would cause asignificant change in dc centering of traverse wa | ||
SONY |
KPR36XBR
|
Broken picture control buttons, replaced front ass'y | Picture up/down buttons broken. | ||
SONY |
CDP302
|
Ams function does not work reliably | Noisy unreliable ams. no other problem noted. | ||
SONY |
SLHF450
|
Noise in playback | During playback noise getting into video resulting in horiz.clicks getting into pix. | ||
SONY |
KV1997R
|
Only power on & no power off, shorted c133 | Only power on, could not power off. sleep light would notcome on at power on. no function. servicer had replaced ic103 and ic105still same problem. had v pulse pin 4, clock ok, reset ok, had noiseat h sync. | ||
SONY |
KPR4600
|
No channel memory,replaced q-308 and d-339 | Above symptoms were intermittent when turning set on and off with power button. reset pulse was insufficient. found a leaky base to emitter q308 and leaky d339. | ||
SONY |
KV2091R
|
Low audio, change value of r842 to 300 ohms | Customers are complaining about the low volume delivered by this model at max setting. |