Repair Tips
Search:
Results: 87715
Results: 87715
Make | Model | Symptom | Problem | Solution | By |
---|---|---|---|---|---|
SONY |
KV1952RS
|
No channel indication, q2002 open | This unit had no led drive for the channel indicator. alsosound, pix, channel controls did not work. it gave every indication of alocked up upc. we found q2002 on m board to be open and causing theproblem. | ||
SONY |
PSLX55II
|
Tonearm not dropping | Tonearm would not drop to record. | ||
SONY |
BMC550
|
Lithium battery | One customer has lost lithium battery already one customerbattery was missing from carton and one wants to purchase replacementjust to be on the safe side. | ||
SONY |
SL2710
|
Unit pulsates between record and pause modes in steady cycle | When entering rec, unit would cycle between rec and pause ata rapid frequency. random pulse at collector of q517, ss-21 board causedproblem. q518 was found defective. replaced q518, unit ok. | ||
SONY |
CDXR7
|
Wrong part number | Transistors q1 and q2 are listed as 8-759-105-29 on page 69of service manual. correct number is 8-729-105-29. -hq comments: we will issue a t/n and s/b. | ||
SONY |
RM704
|
Rm704 is not available | Rm-704 is not available. npc substitute part is rm-708, butshape is not the same. if size and shape is more important to customer,can rm-706 (a-1009-074-a) or rm-705 (not all function) be substitutedsuccessfully? -hq comments: as replacement of units | ||
SONY |
AIR8
|
Display malfunction | Low or no audio, all segments of the display come on when astation is received, but display acts normal in scan mode or when unit isnot tuned onto a station, also display blanks out completely in psb mode. | ||
SONY |
STRAV460
|
Background noise | In fm mode after 45 to 90 minutes there is excessive back-ground noise. also, the sensitivity seems to have decreased. -hq comments: if the problem is in the fm, i would suggest you wouldheat-test q101 rf amp. also check the transistor mechanically, o | ||
SONY |
CDX5
|
Noise | When using a cdx-5, xr-65 and xm-55 and listening to a disc,sound is very clean when listening to either a tape or radio, excessivemotor noise shows up in the system. though, when bypassing the cdx-5 themotor noise disappears. one dealer has tried as m | ||
SONY |
KV25XBR
|
No rgb output | Set had no rgb output when unboxed. scope showed good videoin at ic301 pin 3 and also pin 2 but no video out at pins 32, 33 or 34.a check of supply voltages showed the following: 140 volt line was 130volt. 16 volt line was 15 volt. 8 volt line was 7 | ||
SONY |
BMC110
|
Correction to supplement #1 | Page 8 ref. 334 and 338 reversed in expl. p/n 3-681-404-01(flange 334) 3-681-410-01 (nut 338) -hq comments: we will issue a t/n and s/b regarding this subject. thefollowing will be changed. 1) reverse reference balloons 334 and 338.2) add screw (p/n | ||
SONY |
KV2675R
|
No vip, leaky d-103 | No vip. noise on m2 data line pin 28 ic103 a board.voltage approx. 4.5vdc. when checking m2 line at pin 14 of ic050 tboard could see a faint horizontal pulse. | ||
SONY |
MTL10
|
Repack kit | Approx. 3 months after installation of mtl repack kit(t-998-025-81), ic became defective. only way to get new ic is to consumeentire new repack kit. | ||
SONY |
KV1992R
|
Intermittent remote, corroded plug on remote module | Many complaints on kv-1970, -1971 and -1992 with intermittentremote function. | ||
SONY |
WM10
|
Wrong battery lid | Two different type battery lids produced for wm-f10 may besame problem as wm-f10 technical news a-0062 feb 15, 1985. -hq comments: although both lids are different in color of the sidewall, they are physically compatible and are registered as the samepa | ||
SONY |
KV2670R
|
Cable interference, suggest 220 mhz trap use | Tv on cable. vertical bars channels, k thru w. per the cablecompany, there is a pilot signal at channel j (220mhz). i have not beenable to get a trap at this frequency (220mhz). -hq comments: please try microwave filter company. the address is6743 k | ||
SONY |
XR65
|
Fm drift | Fm would come in with stereo indicator lit when unit was firstturned on. after about 20 minutes stereo led would go out. slightlyadjusting rv4 would turn indicator back on for a short time before itdrifted again. found that by hitting c48 with freeze | ||
SONY |
STRVX5
|
Erratic display and control operation | From a cold start up unit would have no display and all func-tion leds would be lit. after several mins. of being on, display wouldlight, function leds would go out and unit would work and not act up. | ||
SONY |
CDP302
|
Intermittent problem of reading toc | Unit, intermittently, would not read toc. disc motor spinswide open then stops. at other times unit would perform with no problems. | ||
SONY |
KV2670R
|
Bend at top of picture | Bending at the top of the picture. the bending changes wheneither the brightness or picture adjustments are performed. things thathave been tried so far but have not fixed the problem: c532, c534, c547,c548, c229 and pct t503. -hq comments: disable t |