Repair Tips
Search:
Results: 87712
Results: 87712
Make | Model | Symptom | Problem | Solution | By |
---|---|---|---|---|---|
SONY |
SPP11
|
Leaky diode | Even when there was an incoming signal from tell line jack tophoto coupler, the call tone did not ring. | ||
SONY |
PSFL1
|
Intermittent s6 | The unit intermittently would not shut off after the drawerwas fully open. this resulted in the gears grinding. we found s6 to beintermittent. we have also observed that whenever we encounter thiskind of problem that it is necessary to check the mesh | ||
SONY |
CFS88S
|
Burnt switch | Unit has no power or appears to be running on very low supplyvoltage. type of supply (ac, dc internal, or dc external) irrelevant tosymptom. s903 (power switch) has developed high resistance due to contactburning. | ||
SONY |
CDP200
|
Poor contact between clutch and the disc | Unit skips. music comes and goes. noted that tracking errorand sled waveforms would go crazy when problem occurred. tracking errorwould alternate between traverse signal and servo loop signal. we foundthat the disc would wobble just before the proble | ||
SONY |
WMF10
|
Worn take-up reel | Take-up reel drags - causes motor current to exceed 1/2 ampin rwd, and w&f to occasionally rise over 0.25% in fwd. | ||
SONY |
WMF5
|
Open cap on osc circuit | No fm - subbed out osc with generator to verify the fm oscwas dead. | ||
SONY |
STRVX550
|
Missing p/n in manual | Many servicers ask for the part # of the capacitors used inthe hi-fi service bulletin #180. | ||
SONY |
STRVX550
|
Ground connection modification | Tightening ground screen on the main chassis and displayboard does not always resolve the ground problem. the easiest thing todo is to install star washer. | ||
SONY |
STRVX550
|
Static induced onto tv set | When the vx-550 was on and within about 10 feet of a tv (anybrand) static was induced in the picture and sound. we found the multi-vibrator which supplies power to the fluorescent tube filament to be thecause. | ||
SONY |
STRVX200
|
Leaky diode d302 | This unit would intermittently lose station (preset) memory. | ||
SONY |
STRVX4
|
Thermally intermittent ic201 | The am or fm would periodically become distorted and sometimesmute. | ||
SONY |
STRVX4
|
Open c854 | There was no reset pulse for the microprocessor. therefore,the unit acted very strange. for example, memory scan does not go up tomemory 8. | ||
SONY |
MTL10
|
Slide plate sticks | Intermittently the cass. will not retrack back from themechanism to the cass. slider. after unit is unjammed, it will work upto 3 hrs. before failing again. | ||
SONY |
CFSF11
|
Gear on rph shaft cracks | The gear on rph shaft cracks and prevents the head fromturning. if the head turns only part way around, the mechanism will jamand destroy other parts. -hq comments: although the gear is mounted onto the head, the gearcomes with the part as illustrated | ||
SONY |
CDP701ES
|
Rf pll and clv pll out of adjustment | Unit will not track discs with visible defect in program area.some discs track on cdp-101 and cdp-200 with no problem. possible causeof this could be the auto antiskate circuit in the cdp-400 and cdp-701es. -hq comments: careful electrical alignment, p | ||
SONY |
CDP200
|
Rf pll out of adjustment | The unit skipped in play mode. | ||
SONY |
CDP200
|
Focus offset and rf pll out of adjustment | Although the objective lens searches for the focus point andthere is laser light coming out, the disc motor does not turn. | ||
SONY |
CDP101
|
Rf pll and clv pll out of adjustment | The unit does not accept the customer's disc. decca, verdi,la travia (400057-2). it worked fine with yeds-1. | ||
SONY |
CDP101
|
Malfunctioning d/a converter ic507 | The unit had an intermittent low pitched buzz in bothchannels. we found ic507 d/a converter to have an intermittent clock. | ||
SONY |
WMF10
|
Intermittent audio | Ground becomes discontinuous due to excessive lubricant onhead ground plate surfaces. remove lubricant. use sony p-401g to relube. -hq comments: we will issue a bulletin on wm-10 lubrication pointsshortly. |