SONY STRVX6
Missing p/n in manual A servicer had a unit with open diodes d901 and d902. thesediodes are the part of the resistor/diode network (cp001) in the pps.the p/n is not listed in the s/m. -hq comments: cp (composite parts) are not stocked. repairs are to bedone by replacing ba
SONY PSFL9
Irregular guide bar The unit preformed very well except that when the tone armreturned to the rest position it would vibrate during the last inch oftravel. we found the guide bar to be slightly irregular causing the tonearm to slightly bind and vibrate.
SONY D5
Malfunctioning crystal oscillator Only noise was heard in audio.
SONY CDP400
Malfunctioning ic501 Noise in playback (ticking noise), different frequency ofnoise from different discs.
SONY CDP400
Loose wire in cn22 Insert disc, runs fast for 15 sec. then ejects servo.circuits check out ok.
SONY XRM10
No tape ejection Motor would run at all times and tape was difficult orimpossible to eject. press-fitted pin becomes loose. therefore, themotor keeps running. -hq comments: new part has no notch, which presents the pin from becominloose. you can obtain one from rpc/t
SONY TTS81
Missing instructions in manual No instructions are given on how to set tracking force.
SONY TCFX600
Relay not toggling properly In playback, when going from dolby off to dolby c, unitbreaks into oscillation in both channels. when going from dolby b, todolby c, no problem. unsoldering either pin 2 or 8 of ic001 cures theopposite channel.
SONY TCFX7
Incomplete instructions in manual Page 22 of s/m, instructions for servo adjustment areincomplete. step 7 should refer to pin 21 of ic902 for pulse adjustment. -hq comments: as you pointed out, the tp (silk-screened as speed) isnot shown for the #7 in the adjustment procedures. the pi
SONY TAN88B
Incompatible v-fets Replaced v-fets with new ones and power supply fails. butwhen a set of v-fets from another unit are used, unit worked correctly.
SONY STRVX550
Tape deck plugged into ac outlet on back malfunctions Tape deck plugged into this unit stops/starts/rewinds etc.automatically and randomly upon power on/off activation. it is notedthis only happens when the speaker grounds are wired together or when unitis used with a speaker switch box that does not have
SONY PSX75
Defective hall ic d601 The turntable motor did not turn although there was a kickpulse (current) through the motor coil.
SONY PSX75
No stylus force The tone arm did not go down and there was no stylus force.
SONY MTL10
Detection sensitivity adjustment misadjusted Unit would not line up properly to load the first cassette.
SONY M100B
Tape jams The unit jammed the tape intermittently. when it happened,the take up reel was not turning although the capstan and the pinchroller were turning fine.
SONY ICF7750
Open foil trace Sound was very low and distorted or there was no sound atall. we found an open foil associated with r41. the foil looked finebut was open. foil repair resolved the problem. although this appearsto be a straight forward repair, it stumped the technici
SONY CRF320
Bad contact on ss-6 switch The unit came in with very poor sensitivity in am, sw and lw.checked and found there was almost no local oscillator signal at thecenter tap of ift201 in the second mixer circuit.
SONY CDP501ES
Missing ground path At the end of each selection of music unit would go intopause, no matter what position switch s917 was in auto/pause.
SONY XR75B
Jammed tape Tape jams or unit will not take up tape. problem is withpart #318 on p51 s/m. roller bearing on right side of tray is bent andloading mechanism cannot move smoothly.
SONY WMF10
No fm Fm was not working. only white noise was heard. since therewas fm white noise, i suspected rf section was bad.