Repair Tips
Search:
Results: 87709
Results: 87709
Make | Model | Symptom | Problem | Solution | By |
---|---|---|---|---|---|
SONY |
TAAX4
|
Error in manual | On schematic, page 27, and in unit, the capacitor for c905has a value of 0.82 uf at 250 volts. on page 34, in the parts list thevalue listed is 1.2 uf at 250 volts, the part number is shaded becausethis part is critical to the power supply section. -hq | ||
SONY |
STRVX750
|
Ic301 need to be replaced | In reference to t/n #8512, this str-vx750 has the former ic301(8502) which causes the problem that had been thought to only occur inthe early production (806,000) str-vx550. | ||
SONY |
STRVX550
|
Amp overheats | When using amp on a 4Ω load after 5 to 7 minutes powerchip will overheat and short. this is at 50 watts which is the spec. onthe service manual. on 8Ω load at 50 watts, power chip runs extremelyhot, also. -hq comments: we ran our unit into a 4 o | ||
SONY |
STRVX6
|
Leaky p405 | Ones digit of the display always shows 0 or 8. checkedthe waveform at pin 18 of ic401 (u-com) of this unit and the good unit(s/n 804552) as shown below. | ||
SONY |
STRVX4
|
Replacement transistors fail | The 2sc-1826 or 2sc-1986 is used as a regulator in the abovelisted models. when these parts fail and the part 8-729-398-62 is orderedthe part is subbed to a 2sc-2768. -hq comments: 2sc1986 (8-729-398-62) does not sub into a 2sc2768 atkcp. however the | ||
SONY |
STRV45
|
Defective q310 | Hum comes and goes. | ||
SONY |
STP7
|
Defective ic603 and fd701 | This unit would not tune or display the proper characters.we found the upc and display to be defective. | ||
SONY |
SRF70W
|
Defective tuning cap | When tuning to high end am at one point about 1000 khz, amwould sound like it shut off. | ||
SONY |
PSLX5
|
Intermittent switch | The tone arm would go into 45 disc position instead of droppoint for 33 size. only at first cycle, then no more failures. | ||
SONY |
ICFC55W
|
Open foil trace | Clock runs fast 8 minutes per hour. | ||
SONY |
HMK313
|
Poor connection at r605 | No right channel output. found poor connection at r605. | ||
SONY |
FH7
|
Worn driving gear | Upon investigation it appears that gear and fwd cam isstopping at an incorrect position allowing it to wear hub of driving gear. | ||
SONY |
CFS45
|
Proper screws needed | Since the latest (metal type) carrying handle side pieces havebecome available, i have had difficulty finding a usable screw type whichthreads properly into the also new threaded holes in these parts. | ||
SONY |
CDP101
|
Defective cnj36 | With disc in place transport would close but would also rejectit immediately. | ||
SONY |
CDP101
|
Defective clock ckt | Intermittently when unit is first turned on disc motor wouldgo to full speed and stay there until power was turned off. | ||
SONY |
CDP101
|
Red wire cut | After 15 to 30 min, the display will indicate 71 (scan 77.77)in stop mode. these functions also do not operate time, clear, open/close, reset. moving the wires to display pcb effected problem. | ||
SONY |
BM600
|
Hold switch shorts pcb | When the safety hold switch is in its hold position,excessive current (almost short) is drawn from the batteries or externalpower power supply. foil shield (a) section 2-c is usually found to beshorting the solder connections of the function keypad assy. | ||
SONY |
WM4
|
Battery contacts touch ckt | When batteries were installed the holder for battery contactgave way. contacts came in contact with motor mounting plate, causingbatteries to short momentarily when unit was moved or touched causingmotor speed fluctuation and noise in head phone. tappi | ||
SONY |
XM1
|
Defective ic301 and ic102 | The oscillator and its associated amp were shorted on thisunit. naturally there was no pwm output and the sound was very low anddistorted. | ||
SONY |
TCFX66
|
Loose chassis ground screw | User complained remote control (rm50) would only work after1-2 hour warm up. |