Make Model Symptom Problem Solution By
SONY KV1515
Incorrect tuning operation Unable to tune position #1 to the correct channel on any ofthe 3 band selections. all other positions function normally. foundthat moving band switch at position 13 while in position 1 viewing modewould cause deteriorating effect on position 1 tuning,
SONY KV1515
No low vhf Set would not tune above channel 2, traced to leaky vc drivertransistor.
SONY KV1217
Vertical foldover, replaced c524 Vertical foldover with blanking spot on right upper corner andjittery picture. found c524 installed backwards during manufacturing.
SONY KV1217
No uhf, replaced tuner No uhf.
SONY KV1214
Picture interference Interference in shape of two vertical lines on left side ofscreen. waveform at input to blanker stage was distorted.
SONY KV4000
Tuning would not lock Will not lock on station when cold, after unit warms up willwork properly. found waveform at pin 8 of ic134 incorrect.
SONY KV3000R
No remote functions Upon inspection after delivery to dealer it was noted thatthere were no remote functions and only limited manual functions. powercame on immediately after engaging master power switch and set could notbe turned off except with same. the only other manu
SONY KV2643R
Retrace lines, replaced r749 Excessive brightness/retrace lines. rv2203, rv304, rv701 haveno effect, pin 12 crt = 850v.
SONY KV2145R
Dark picture, resolder r054 Raster goes dark with sound bars, sound normal, then normalpicture jumps back. found r054 mounted on the print side, cold soldered.
SONY KV2145R
H tearing & flashing, resolder anode lead R067 on mf board overheats. noticed intermittent horizontaltearing and flashing across screen. found anode lead which is a plug intype, was not making firm contact.
SONY KV1946R
Shut down, l503 broken off Set would go into shut-down mode immediately at turn on.i verified horizontal oscillator and b+ circuits were operating properly.i then noticed that the coil l503 was broken off of the connection onpc board.
SONY KV1923
Tuning shifts Channels would program correctly. if set was on channel 2and moved to channel 8 then back to channel 2, channel 2 would not comein. same with channel 8 when set was returned to this channel. thiswould also happen if the set was turned off and back on.
SONY KV2647R
Shut down with jig, ground hvr This particular unit shut off instantaneously when power wasturned on. it happens only when chassis was attached to the jig. most ofthe time technicians spent useless hours to find out that the ground onthe hvr was missing (usually a screw grounds the
SONY KV2645RS
Pin cushion, add resistor in series with r809 Pincushion correction at top and bottom near the corners isalmost null. -hq comments: to correct the problem place a 15Ω 1w resistor inseries with r809 (100Ω 1w) and readjust pin phase and pin ampcontrols.
SONY KV2643R
No channel lock, replaced c206 Except on low band this unit keeps on scanning stations.ch. 2, 4, 5 could be tuned in but slightly have weak video (slight snow).found c206 leaky causing a drop, at pins 26 and 28 to 1.7 volts insteadof 4.6 volts.
SONY KV1546R
Vert roll, intermittent vert collapse, replaced c508 Set operates fine for 1/2 to one hour then starts to roll,then vertical collapse. found c508 improperly installed (reversepolarity).
SONY KV1217
Picture distortion, see modification below Horiz. centering adjustment will not shift picture far enoughtowards the right. center adjustment only expands the picture. -hq comments: try the following circuit modification. place the horiz.centering r. position. the r1, r2, c1 values shown shoul
SONY KV1207
No channel look Set changes channel by itself usually ending on ch. 13position.
SONY KP5040
Incorrect mechanical function, use of loctite When unit was turned on the mirror door would extend about2/3 of the way out and start clicking. the motor would continue to runand not shut off. disassembly revealed the retaining nut on the driveshaft had worked loose allowing the left hand side door
SONY KV2647R
No picture, open r057 and prescaler, R057 resistor open (mf board). no problem found in reg.circuit. solder splash on feed thru terminal of prescaler.