HITACHI NP83CQ
Works for 2mins then channel display goes out , pi No 5v pin 20 mab8422 5v reg or bridge rectifier on citac panel
HITACHI NP83CQ
Weak contrast, no col - sound ok, controls have no effect Ic501 tda2561a
HITACHI NP83CQ
Trips into st/by Ok on dummy load - loptx pt no 2433752
HITACHI NP83CQ
Red raster & white hor lines on txt Tda3561a u/s
HITACHI NP83CQ
Pic made up of large white dots Ic501 tda3561a
HITACHI NP83CQ
No s/v , in av mode Zd1438 12v zener
HITACHI NP83CQ
No raster & no channel change. Q1454 ( cita pcb )
HITACHI NP83CQ
No raster - sound ok. R720 , r721 ( 3.9k ) gone high.
HITACHI NP83CQ
No raster - sound ok No lum from ic501, sandcastle pulse low; r720/721 1m hi res
HITACHI NP83CQ
No picture or sound psu & line ok 12v rail low r716 oc or high 2r
HITACHI NP83CQ
No picture just vertical lines Same with txt pcb removed - tda3561a decoder chip u/s
HITACHI NP83CQ
No cold start C908 33µ
HITACHI NP83CQ
Int/crackly sound Tone control under front flap noisy
HITACHI NP83CQ
Height reduces on warm up Tda3651a field chip u/s
HITACHI NP83CQ
Frame - foldover after 10 mins. C613 ( 100u f ) o/c.
HITACHI NP83CQ
Field collapse or field flutter C603 1uf tantalum
HITACHI NP83CQ
Field bounce - top inch of pic int disappears C613 100n across field scan coils
HITACHI NP83CQ
Dead with "1" in display No b+ volts until loptx removed (130v) - new loptx cured it & ht normal at 110v
HITACHI NP83CQ
Dead Str6020 s/c; r715 2r2 o/c; 2a fuse o/c; r901 6r 6w o/c; tda3651 u/s
HITACHI NP83CQ
Dead Won't work on dummy load unless loptx removed - loptx faulty