Search: hitachi
Results: 1065
Make Model Symptom Problem Solution By
HITACHI G8Q
Int crackle on sound Replace c1522 ( 1nf ) c460 ( 100nf ) c454 ( 22nf ) c453 ( 22nf )
HITACHI G8Q
Int corruption of stored data - all sigs lost & reverts to chan 0 5v supply to txt pcb int lost - coil on back of board in supply from 8v reg ic001 line was dry jointed
HITACHI G8Q
Int comes on into standby from cold. Thermistor th902.
HITACHI G8Q
Int blank screen/snowy/flickering Ripple on 12v line caused by c932 1000µ corrupting micro
HITACHI G8Q
Ht high at 165v & won't adjust Zd941 ref diode bzv10 leaky
HITACHI G8Q
Horizontal lines when warmed up Tuner thermally defective
HITACHI G8Q
Horizontal lines appear when set is warm Tuner goes thermally defective
HITACHI G8Q
Field collapse No supply to ic601 fop chip - r715 1r fusible o/c & chip u/s
HITACHI G8Q
Excessive width - no e/w coection D705 , c714 byw96d and 27nf
HITACHI G8Q
Excess brill / fb lines 200v video supply missing - r720 2r0 o/c
HITACHI G8Q
Eeprom keeps becoming corrupted Degaussing positive int arcing
HITACHI G8Q
Display corrupt Check q1502/3/4/5 - q1505 was leaky bc548
HITACHI G8Q
Diagonal bands of interference - esp in txt C932 470µ 16v
HITACHI G8Q
Dead with line driver turned fully on and led not Check around ic1502 ( saa1293 ) for activity if none replace x1501 crystal
HITACHI G8Q
Dead with blackened mains fuse Melted pvc tape from degaussing coils touching audio amps heatsink
HITACHI G8Q
Dead or int start up/off Start up therm th902 o/c
HITACHI G8Q
Dead- fuse blackened Check th902 thermistor
HITACHI G8Q
Dead apart from tripping Txt panel dis'd & trip stops - c933
HITACHI G8Q
Dead apart from chan no. 12v supply only 5v - c933 2200µ 25v
HITACHI G8Q
Dead after smoking C715 in e-w cct dry joints