HITACHI G8Q
No sound/pic - blank raster when a1 increased Dry joint connection to sleeved wire that links 8v supply to ic001 5v reg
HITACHI G8Q
No sound picture goes white Ic952 12v reg us
HITACHI G8Q
No sound op stage ok D401 in if can oc
HITACHI G8Q
No sound int goes to stby Ic1501 micro u/s.
HITACHI G8Q
No sound D701 1n4148 & tda2579 timebase chip
HITACHI G8Q
No sound D701 ( 1n4148 ) , tda2579.
HITACHI G8Q
No raster - field collapse Check pin 9 ic601 if low (should be 9v) check r715 1r for o/c
HITACHI G8Q
No osd R008 470k o/c or dry jointed
HITACHI G8Q
No or only part of display shows Check ic1501 saa1293h by subst - if only part of display showing check r15060r1513 100r
HITACHI G8Q
No eht & 12vsupply only 5v C933 2200µ 25v leaky
HITACHI G8Q
Narrow & pic shift to right with weak sync Tda2579a & check r725 470k
HITACHI G8Q
Memory lost Check for 3v at ic1502 mda2062 memory chip & r1519 27k 1w
HITACHI G8Q
Line hold lost Ic431 m51551p on if panel
HITACHI G8Q
Lack of sync Q2110 bc548b on txt pcb
HITACHI G8Q
Int trip R910 5r increased res - could be ic1501 micro
HITACHI G8Q
Int to start up Th902
HITACHI G8Q
Int st/by R718 51k hi res replaced - triggering crowbar thy
HITACHI G8Q
Int loss of green Rgb o/p tr bf459 faulty - can use bf462 in lieu
HITACHI G8Q
Int fails to start. Th902 thermistor
HITACHI G8Q
Int cutting out after repair to power supp. Change r910 , c908 , vr901. set pot to 12 oclock *******discharge c906 before any work*******