Search: mitsubishi
Results: 1346
Make Model Symptom Problem Solution By
MITSUBISHI CT25A4STX CT29A
Dead , no line drive , check for momentary very low Requires feedback from line stage or will shut down. o.c. pin , check for very low amplitude pulse , on scope , replace drive tran
MITSUBISHI CT25A4STX
No sound, text or nicam Fit ic702 kit
MITSUBISHI CT25A4STX
Impurity - degaussing faulty Replaced o/c q903 jc501r - used bc639 in lieu (same pin out) - in degaussing relay driver.
MITSUBISHI CT25A4STX
Dead Replace tea2261, d909 and q552
MITSUBISHI CT25A4STX
Buzzing on lh speaker only C909 - increase to 1000µ
MITSUBISHI CT25A3STX
Dead - keeps blowing loptrs Dry joint on wire link near loptr
MITSUBISHI CT25A3STX
`dead & no st/by led C906 10µ 50v hi esr, q552 2sd1878 leaky - used 2sd1555 in lieu
MITSUBISHI CT25A2STX
Sometimes trips when brought out of sby ( ht risin C609 47mfd
MITSUBISHI CT25A2STX
No go red led comes on then green led then both go D909 4.3v zener
MITSUBISHI CT25A2STX
Dead-int. Q501 low gain
MITSUBISHI CT25A2STX
Dead - q901 s/c. Fit mod kit ( wve 77901 ) r901 , d908 , q901 , c908 to 2700pf , c966.
MITSUBISHI CT25A2STX
Cuts out at sw on - ht high at 180v (145v) - will come on eventually C906 47µ 63v in base q901 (overvolts prot)
MITSUBISHI CT25A2STX
Cuts off totally 5 seconds after switch on keep pressing Measure h.t if rises up to 180v then back to 145v replace c906 ( 47uf )
MITSUBISHI CT25A2STX
Colour sub-caier off speed C604 open
MITSUBISHI CT2555TX
Wavy lines at sw on - clear when heated C920 470µ 25v in reg stage next to large heatsink
MITSUBISHI CT2555STX
Very weak luma with flaring. Clean glue off luma /chroma board & reconnect gap left in tracks.
MITSUBISHI CT2555STX
Picture wobble / line tearing type fault Check for dry joints at lopt screen where it connects to print
MITSUBISHI CT2555STX
No luminance R286 o/c 100Ω
MITSUBISHI CT2555STX
No lum - txt & contrast ok R286 100r o/c pin 11 ic602
MITSUBISHI CT2555STX
No lum No 12v to q253 as print o/c top edge of dec pcb