MITSUBISHI CT2206
Frame -height reduced & poor line convergance Dj on earth pin of convergence pot.
MITSUBISHI CT2206
Frame height & poor line convergance intermit Dj on earth pin of convergence pot.
MITSUBISHI CT2206
Dead - ht present at lop Big fusible resistor above lop tr sprung open - no other ff
MITSUBISHI CT21M5BT EE4
Int loss of pic - sound still present Invisible dry joint ic650 tea5101b rgb o/p chip on crt base
MITSUBISHI CT21M5BT
Dead or int start up Check r704 for o/c sometimes marked r703 on pcb
MITSUBISHI CT21M5B CT25M5B
Tuning drift mainly at top end of band Add ( 180k ) & diode ( in4148 ) in series cathode of diode to 5v pin 6 tuner & res to tuning voltage line pin 2
MITSUBISHI CT21M5B
Under very poor signal conditions "herringbone" pa Fit specially screened rf lead between vcr and tv ptno h24p001010
MITSUBISHI CT21M5B
Failure of q552 Order & fit avm5kit
MITSUBISHI CT21M5 EE4
No txt or auto tune/store Eset options in eeprom from service mode
MITSUBISHI CT21M5 EE4
Dead - blowing soc2000 cct prot Microprocessor s/c +5v pin to chassis
MITSUBISHI CT21M3TX
No store tune & r/c responses spurious X24c04p eeprom & check caps in psu - used sda2516 in lieu
MITSUBISHI CT21M3TX
No signals R702 22k in 33v line o/c
MITSUBISHI CT21M3STX
Low ht Q953 jc501 pt no 260p543050
MITSUBISHI CT21M1TX
Unstable pic when cold C905 470µ 25v in pri psu
MITSUBISHI CT21M1TX
Unstable pic on dark scenes C906 47µ 25v in psu
MITSUBISHI CT21M1TX
Starts + shuts down immediately Optocoupler pc951 or d905 , r905
MITSUBISHI CT21M1TX
Field chip int blows C909 2µ2 in psu int causing excess ht
MITSUBISHI CT21M1BM CT25M1
Popping noise in stby works ok when on Q951 q952 or drys on connector pb , r954 , r974 , r985
MITSUBISHI CT21M1BM
Sides of pic moving in & out C906 in psu - also check other caps in psu
MITSUBISHI CT21M1BM
Red led lit but wont come on Dry joints on cf701 4mhz crystal on pins 28 and 29 ic701