Search: mitsubishi
Results: 1346
Make Model Symptom Problem Solution By
MITSUBISHI CT2125TX
Large black square int covers screen, floats left or right & int poor contrast C959 100µ 25v hi esr causing low 5v supply from reg - also check c964 10µ 50v, c962 100µ 50v, c905 470µ 25v
MITSUBISHI CT2125TX
Int blowing line transistor. Str54041 , clean & resolder pins of line driver transformer.
MITSUBISHI CT2125TX
Dead. D909 ( 3v zener ) s/c.
MITSUBISHI CT2125TX
Dead - standby light flashing. Ht @ 35v , d961 ( 6.2v zener ) leaky.
MITSUBISHI CT2124BM
Not switching on from cold Replace c964 100mfd50v
MITSUBISHI CT2124BM
Loss of tuning memory Check ic702 for 5v at pin1 & -30v at pin 2. if missing check back to psu, if ok replace chip.
MITSUBISHI CT2124BM
Dead C962 100µ & c974 10µ in -30v supply6had leaked & corroded adjacent print, also c965 220µ leaky in 12v supply
MITSUBISHI CT2124BM
Dead C964 100µ50v o/c
MITSUBISHI CT2117BM
Col cycles thro' auto grey scale at sw on with flashing lines Caused by high ht - c911 33µ 50v, c910 33µ 50v & c913 100µ all hi esr
MITSUBISHI CT2101TX
St/by only Ht low at 37v. c910 & 911 1µ 50v
MITSUBISHI CT2101TX
No pic - no htrs crt R670 on crt base dry joints
MITSUBISHI CT2101T
Blank raster & no sound. R178 o/c , or o/c print between r178 & q241.
MITSUBISHI CT2101
Smelly smoke.
MITSUBISHI CT2101
Poor remote operation. Filter coil l992 replace with mod type.
MITSUBISHI CT2027TX
Sound - int or no sound. High res connection on ic351 holder.
MITSUBISHI CT2027TX
Int or no colour. D209 ( 1s2076 ) check by replacement.
MITSUBISHI CT2023B
Dead / int dead Dry joints line dr tfmr & r581
MITSUBISHI CT2004B
Frame - height varing. Vr401 , ic401 ( ha11414 ) , f572 high.
MITSUBISHI CT1905BM
Sby light on , power supp running but dead . no lin C501 , 100mfd , 25v on signals pcb
MITSUBISHI CT186
No luminance. Q231 ( 2sc2236 ) 12v reg.