PHILIPS GR2.4
No e/w correction. Check transistor t7530 e/w circuit (5322 130 60159)
PHILIPS GR2.4
No contrast or red in txt Ic7309 pin 2 volts low (2v) . c2358 22n leaky
PHILIPS GR2.4
Motorboating sound in st.by. supply: "on"=143.6v, "st.by"=78v Replace ic7240 (tda1521; 4822 209 73853)
PHILIPS GR2.4
Low contrast on teletext Replace the following items: items 3347, 3348 and 3349 should be 820Ω resistors (4822 116 52231) items 3766, 3767 and 3769 should be 5k6Ω resistors (4822 116 52289)
PHILIPS GR2.4
List of the microprocessors used in gr2.4 List of the microprocessors used in gr2.4 dev. code: 4wecor-2.2 supply code: otp description: stereo (eng,fin,dan,swe,nor,spa) crystal: 8.00 service code: 4822 209 33827
PHILIPS GR2.4
List of the microprocessors used in gr2.4 List of the microprocessors used in gr2.4 dev. code: 4wecor-2.0 supply code: otp description: stereo (eng,ger,fre,ita,dut,por,spa crystal: 8.00 replacement: 4822 209 33918
PHILIPS GR2.4
List of the microprocessors used in gr2.4 List of the microprocessors used in gr2.4 dev. code: 4necor-1.2 supply code: otp description: stereo (eng,fin,dan,swe,nor,spa) crystal: 8.00 service code: 4822 209 33827
PHILIPS GR2.4
List of the microprocessors used in gr2.4 List of the microprocessors used in gr2.4 dev. code: 4wecor-1.2 supply code: otp description: stereo (eng,ger,fre,ita,dut,por,spa) crystal: 8.00 service code: 4822 209 33918
PHILIPS GR2.4
List of the microprocessors used in gr2.4 List of the microprocessors used in gr2.4 dev. code: 4wecor-2.0 supply code: otp description: stereo (eng,fin,dan,swe,nor,spa) crystal: 8.00 replacement: 4822 209 33827
PHILIPS GR2.4
List of the microprocessors used in gr2.4 List of the microprocessors used in gr2.4 dev. code: 4eecor-1.2 supply code: otp description: stereo (eng,ger,fre,hun,czec,rus,pol) crystal: 8.00 service code: 4822 209 52643
PHILIPS GR2.4
List of the microprocessors used in gr2.4 List of the microprocessors used in gr2.4 dev. code: 4wecor-2.2 supply code: otp description: stereo (eng,ger,fre,ita,dut,por,spa) crystal: 8.00 service code: 4822 209 33918
PHILIPS GR2.4
In txt mode vert. lines are bended. fly-back lines in ext. mode. Readjust vg2 voltage; must be 130-145v
PHILIPS GR2.4
Frame instable, amplitude varies. Check connectors between frame output stage and deflection yoke. if scanning module (1009) present, pay special attention to connectors s12 and s13 on this module.
PHILIPS GR2.4
Flickering picture, stripes Remount eht cable.
PHILIPS GR2.4
Flickering colours. Check and replace if necessary ic7306 (tda4657/v2; 4822 209 33671).
PHILIPS GR2.4
Field lin - lack of height R3503 4r7 o/c
PHILIPS GR2.4
Field - lack of height Tr7546 bc848 sm
PHILIPS GR2.4
E-w faulty E-w tr 7533 bd440 on crt base & 7530 bc846 sm tr next to it & check c2550 680n 250v
PHILIPS GR2.4
Error in product survey 1995-4 (4822 727 20893) Error in product survey 1995-4 (4822 727 20893 the code number of position 2a (4822 458 50564) of styling 90 is not correct the correct code number is 4822 458 10475.
PHILIPS GR2.4
E/w distortion. The cause of this fault was c2302 on the small sub board on the teletext p.c.b.