Search: philips
Results: 14244
Make Model Symptom Problem Solution By
PHILIPS 5240
Rope effect on right hand side. R3191 1kr o/c.
PHILIPS 2550
No field scan ( approx 2" ) R3511 high
PHILIPS 2550
Dead-loud tripping noise D6845 ( surface mount ) short
PHILIPS 1002
Dead - 140v/285v rail ok. R561 ( 2 2r ) high.
IBM OU PHILIPS G54 IBM IGUAL 15B2322Q PHILIPS
Red missing Changed r3725 (kinescope board)
IBM OU PHILIPS G54 IBM IGUAL 15B2322Q PHILIPS
Red missing Changed r3725 (kinescope board)
IBM OU PHILIPS G54 IBM IGUAL 15B2322Q PHILIPS
Red missing Changed r3725 (kinescope board)
PHILIPS 20GL1045
Little contrast Resist. 3555 (27k) aberto
PHILIPS 14GL1010
GR1-AL
It doesn't turn on and the r505 heats up a lot D147 (zener de 12v)
PHILIPS 14PT100G/78R
L7L
No characters R3683 (100k)
PHILIPS 14PT100G/78R
L7L
No contrast R3460(27k)
PHILIPS 14PT519A
Intense noisy sound Transistor 7561
PHILIPS 14PT110
With delay lines R407
PHILIPS 20PT558A
Turns off intermittently Transistors 7461 and 7463
PHILIPS 29GX1899
Dead R3461 of 1k
PHILIPS 29PT5632/78R
NI
Red retrace lines and then turning off Of 7,200 trans. horizontal 7461 and 7462 and head of 47 mf.
PHILIPS 14PT539
NI
Audio popping...normal image. Leaky 7561 transistor.
PHILIPS 14PT110
Inoperative. Capacitor c2540 (100uf x 25v).
PHILIPS FW650C
Functions vary by themselves... Capacitor c2550 (0,22uf x 16v).
PHILIPS 29PT552A
Works for some time and then turns off. Transístor tr7461 (bc337).