PHILIPS |
5240
|
Rope effect on right hand side. | R3191 1kr o/c. | ||
PHILIPS |
2550
|
No field scan ( approx 2" ) | R3511 high | ||
PHILIPS |
2550
|
Dead-loud tripping noise | D6845 ( surface mount ) short | ||
PHILIPS |
1002
|
Dead - 140v/285v rail ok. | R561 ( 2 2r ) high. | ||
IBM OU PHILIPS |
G54 IBM IGUAL 15B2322Q PHILIPS
|
Red missing | Changed r3725 (kinescope board) | ||
IBM OU PHILIPS |
G54 IBM IGUAL 15B2322Q PHILIPS
|
Red missing | Changed r3725 (kinescope board) | ||
IBM OU PHILIPS |
G54 IBM IGUAL 15B2322Q PHILIPS
|
Red missing | Changed r3725 (kinescope board) | ||
PHILIPS |
20GL1045
|
Little contrast | Resist. 3555 (27k) aberto | ||
PHILIPS |
14GL1010
GR1-AL |
It doesn't turn on and the r505 heats up a lot | D147 (zener de 12v) | ||
PHILIPS |
14PT100G/78R
L7L |
No characters | R3683 (100k) | ||
PHILIPS |
14PT100G/78R
L7L |
No contrast | R3460(27k) | ||
PHILIPS |
14PT519A
|
Intense noisy sound | Transistor 7561 | ||
PHILIPS |
14PT110
|
With delay lines | R407 | ||
PHILIPS |
20PT558A
|
Turns off intermittently | Transistors 7461 and 7463 | ||
PHILIPS |
29GX1899
|
Dead | R3461 of 1k | ||
PHILIPS |
29PT5632/78R
NI |
Red retrace lines and then turning off | Of 7,200 trans. horizontal 7461 and 7462 and head of 47 mf. | ||
PHILIPS |
14PT539
NI |
Audio popping...normal image. | Leaky 7561 transistor. | ||
PHILIPS |
14PT110
|
Inoperative. | Capacitor c2540 (100uf x 25v). | ||
PHILIPS |
FW650C
|
Functions vary by themselves... | Capacitor c2550 (0,22uf x 16v). | ||
PHILIPS |
29PT552A
|
Works for some time and then turns off. | Transístor tr7461 (bc337). |