Make Model Symptom Problem Solution By
PHILIPS 14PV162
Codenumber information The codenumber for the spacer between on/off switch and the knob (pos 3) is 4822 402 10702.
PHILIPS 14PV162
Codenumber information Please add following codenumbers to the service manual: lift-flap 14pv162/01 : 4822 443 10402 lift-flap 14pv162/02 : 4822 443 10402 spring for lift-flap : 4822 492 70896
PHILIPS 14PV162
Codenumber correction for deck-up (ic7410) The codenumber for the deckprocessor was wrong in the first service manual (4822 726 15451). in service information tvcr96-01 and in the new manual the correct codenumber is given. the codenumber for the deck-up for sets with non-turbo drive is: 4822
PHILIPS 14PV162
Codenumber correction The codenumber of pos. 1701 (tuner) for 14 inch sets with iec input is 4822 210 10691 (uv916s).
PHILIPS 14PV162
Calling installation menu The installation menu is activated by the following procedure: - switch on the set by means of the stop key. - press simutaneously the cursor left and the cursor right key on the remote control.
PHILIPS 14PT156B
No pic (field collapse) - sound ok R3449 4r7 feed res to fop chip o/c - no other fault detected
PHILIPS 14HT3303
Service code of the fm-radio tuner. In the partslist of the radio-sp/ls-vbatt panel of the chassis manual l9h.2e, the service code of the fm-radio tuner item 1901 was not indicated. the service code is 9352 632 70112
PHILIPS 14CN3001/05
Int low contrast Check preset res (chan scan) isn't shorting to crt aquadag
PHILIPS 14CN2201
Dead - correct 100v ht on dummy load Scan coils - had arced across rubber wedge
PHILIPS 12TVCR240/05
St/by only - no line drive Ug06b clamp diode leaky
PHILIPS 12B312/15S
Dead. Drys on sub pcb & bu type regulator.
PHILIPS 10CX1120/05R
Power supply working but no line drive. Changed the following t539 / t534 / r537 / r502. lopt faulty
PHILIPS 10CX1120/05
Raster - distorted & no frame sync. Ske bridge recy.
PHILIPS 10CX1120/05
Dist raster & no field sync at sw on - clears aft 10 mins Mains bridge rect int goes o/c
PHILIPS 10CX1120/05
Dead - micro tms3757anl-10 T273 bc557 s/c in av/rf sw cct also
PHILIPS 10CX1120
Servicing the philips 10cx1120 See tv mag jan 1995
PHILIPS 10CX1120
Field scan erratic with cramping across centre C582 10nf ceramic cap leaky - pin 20 tda1770
PHILIPS 10CX1120
Field int cramps , sometimes collapses C582 10nf on pin 20 tda1770 field ic
PHILIPS 10CX1120
Dead. T9629 ( buz71 ) s/c , plus drys around loptx.
PHILIPS 10CX1120
Dead on battery - ok on mains C23 1µ in psu - also d37 o/c causing 8v supply to be slightly high (did not affect operation)