PHILIPS |
14PV162
|
Codenumber information | The codenumber for the spacer between on/off switch and the knob (pos 3) is 4822 402 10702. | ||
PHILIPS |
14PV162
|
Codenumber information | Please add following codenumbers to the service manual: lift-flap 14pv162/01 : 4822 443 10402 lift-flap 14pv162/02 : 4822 443 10402 spring for lift-flap : 4822 492 70896 | ||
PHILIPS |
14PV162
|
Codenumber correction for deck-up (ic7410) | The codenumber for the deckprocessor was wrong in the first service manual (4822 726 15451). in service information tvcr96-01 and in the new manual the correct codenumber is given. the codenumber for the deck-up for sets with non-turbo drive is: 4822 | ||
PHILIPS |
14PV162
|
Codenumber correction | The codenumber of pos. 1701 (tuner) for 14 inch sets with iec input is 4822 210 10691 (uv916s). | ||
PHILIPS |
14PV162
|
Calling installation menu | The installation menu is activated by the following procedure: - switch on the set by means of the stop key. - press simutaneously the cursor left and the cursor right key on the remote control. | ||
PHILIPS |
14PT156B
|
No pic (field collapse) - sound ok | R3449 4r7 feed res to fop chip o/c - no other fault detected | ||
PHILIPS |
14HT3303
|
Service code of the fm-radio tuner. | In the partslist of the radio-sp/ls-vbatt panel of the chassis manual l9h.2e, the service code of the fm-radio tuner item 1901 was not indicated. the service code is 9352 632 70112 | ||
PHILIPS |
14CN3001/05
|
Int low contrast | Check preset res (chan scan) isn't shorting to crt aquadag | ||
PHILIPS |
14CN2201
|
Dead - correct 100v ht on dummy load | Scan coils - had arced across rubber wedge | ||
PHILIPS |
12TVCR240/05
|
St/by only - no line drive | Ug06b clamp diode leaky | ||
PHILIPS |
12B312/15S
|
Dead. | Drys on sub pcb & bu type regulator. | ||
PHILIPS |
10CX1120/05R
|
Power supply working but no line drive. | Changed the following t539 / t534 / r537 / r502. lopt faulty | ||
PHILIPS |
10CX1120/05
|
Raster - distorted & no frame sync. | Ske bridge recy. | ||
PHILIPS |
10CX1120/05
|
Dist raster & no field sync at sw on - clears aft 10 mins | Mains bridge rect int goes o/c | ||
PHILIPS |
10CX1120/05
|
Dead - micro tms3757anl-10 | T273 bc557 s/c in av/rf sw cct also | ||
PHILIPS |
10CX1120
|
Servicing the philips 10cx1120 | See tv mag jan 1995 | ||
PHILIPS |
10CX1120
|
Field scan erratic with cramping across centre | C582 10nf ceramic cap leaky - pin 20 tda1770 | ||
PHILIPS |
10CX1120
|
Field int cramps , sometimes collapses | C582 10nf on pin 20 tda1770 field ic | ||
PHILIPS |
10CX1120
|
Dead. | T9629 ( buz71 ) s/c , plus drys around loptx. | ||
PHILIPS |
10CX1120
|
Dead on battery - ok on mains | C23 1µ in psu - also d37 o/c causing 8v supply to be slightly high (did not affect operation) |