Philips Repair Tips
Search: philips
Results: 14208
Results: 14208
Make | Model | Symptom | Problem | Solution | By |
---|---|---|---|---|---|
PHILIPS |
14PV163/05
|
Codenumber information - new software | A new software version (ptcp2-7) is available for the control up (ic 7801). service codenumber is 4822 209 15271. this new version is only used in the following sets: 14pv263/01, 14pv162/01, 14pv162/05, 14pv162/07, 14pv163/05, 14pv163/05h, 14pv263/01 | ||
PHILIPS |
14PV163
|
Spare part information | Sets produced from week 9608 until 9647. motor holder with reverse prism included: in sets produced before week 9647 the reverse prism is a fixed part of the chassis and not available as a spare part. from week 9647 onwards a motor holder (pos.40) with | ||
PHILIPS |
14PV163
|
Reverts to st/by at sw on | Sw tr7352 in middle of pcb | ||
PHILIPS |
14PV163
|
Key set | The key set assy has been codified for all b-range tvcr's. this will allow to change the keys without having to change the complete frame. servicenr. 4822 410 11075 - key set for: 14pv263/01/02/08/13 - 14pv264/39 - 14pv163/05 - 14pv172/01/05/08/13/39 - | ||
PHILIPS |
14PV163
|
Codenumber information | The codenumber for the spacer between on/off switch and the knob (pos 3) is 4822 402 10702. | ||
PHILIPS |
14PV162/07
|
Codenumber information | A new software version (ptcp2-7) is available for the control up (ic 7801). service codenumber is 4822 209 15271. this new version is only used in the following sets: 14pv263/01, 14pv162/01, 14pv162/05, 14pv162/07, 14pv163/05, 14pv163/05h, 14pv263/01 | ||
PHILIPS |
14PV162/05
|
Codenumber information | A new software version (ptcp2-7) is available for the control up (ic 7801). service codenumber is 4822 209 15271. this new version is only used in the following sets: 14pv263/01, 14pv162/01, 14pv162/05, 14pv162/07, 14pv163/05, 14pv163/05h, 14pv263/01 | ||
PHILIPS |
14PV162/02
|
Option code: 00972 | From week 02/97 onwards the option code is printed on the typesticker. always use this code ! for early sets without this information on the typesticker, the option code is: 00972 | ||
PHILIPS |
14PV162/02
|
New vps ic sda5642-6 (pos. 7840) | Since production week 9741 a new vps ic pos. 7840 (sda5642-6) is introduced in production. this ic is not compatible with the previous one. when ordering, look at the printing on the ic ! old: sda 5642-5 - codenumber 4822 209 32728 new: sda 5642-6 - | ||
PHILIPS |
14PV162/01
|
Option code: 00396 | From week 02/97 onwards the option code is printed on the typesticker. always use this code ! for early sets without this information on the typesticker, the option code is: 00396 | ||
PHILIPS |
14PV162/01
|
Codenumber information | A new software version (ptcp2-7) is available for the control up (ic 7801). service codenumber is 4822 209 15271. this new version is only used in the following sets: 14pv263/01, 14pv162/01, 14pv162/05, 14pv162/07, 14pv163/05, 14pv163/05h, 14pv263/01 | ||
PHILIPS |
14PV162
|
Tuner modification | An early production problem appears on these sets: the agc voltage supplied to the tuner 1 is too high (app. 8.8v) in comparison to the supply voltage (5v). it results in a wrong correction of the agc loop when the antenna's signal is too low (about 1,5mv | ||
PHILIPS |
14PV162
|
Start up problems | When the set is switched on by the mains-switch while a cassette is in the set, the front led starts blinking, but the set doesn't start. solution: check the primary voltage (ubat) and adjust this for 14" sets to exactly 101.5 volt. (see chapter 3.1.1 | ||
PHILIPS |
14PV162
|
Spare part information | If the lever inside the mains-switch is broken, the switch doesn't remain in the "on" position. solution: replace the switch by a new one. improved switches of a newer production range are on stock. (4822 276 13542) | ||
PHILIPS |
14PV162
|
Spare part information | A repair kit , containing pulley shaft + worm shaft (pos. 47+48) is delivered with codenumber 4822 310 10657. this kit can be used for all turbo- and eco mechanisms ! | ||
PHILIPS |
14PV162
|
Set produces audible noise in stand-by | Add a small lebl (leading edge blanking) pcb, to avoid auto oscillation of transformer 5330 (or 5331). a modification letter is included with the lable pcb. this pcb is available with service nr. 4822 214 12173. since production week 9723 this circuit is | ||
PHILIPS |
14PV162
|
Preventive tip | If fet 7352 is found to be defective, it is advised to mount a 15 v zenerdiode (bzx79-c15) between the drain and the gate. mount cathode to gate and anode to drain. codenumbers: fet 7352: 4822 130 60838 zener (bzx79-c15): 4822 13034281 introduc | ||
PHILIPS |
14PV162
|
Modification | From week 9644 onwards, the following modifications are done on the small signal board: 2076 / 470pf 5% is deleted. 3075 / 33k 5% is deleted. 4999 / chip jumper / 4822 051 20008 is inserted in place of 2076. the rc differentiator was not necessary whe | ||
PHILIPS |
14PV162
|
Memory erase procedure | The contents of the memory can only be cleared via the service mode. this option is not available for end users. (risc of destroying option codes). service mode: press "stop" on remote control and "play" on the set for 5 seconds. select the second page | ||
PHILIPS |
14PV162
|
Key set | The key set assy has been codified for all b-range tvcr's. this will allow to change the keys without having to change the complete frame. servicenr. 4822 410 11069 - key set for: 14pv162/01/02/05/07/08/13/58 - 14pv170/05 - 14tvcr240/01n. |