PHILIPS 14TVCR240
Modification picture tube From production week 9610 onwards, an orion picture tube was mounted. the codenumber was 4822 131 11075. together with this picture tube capacitor c2586 has been changed to 8 nf - 1600 v. codenumber 4822 121 70629. for replacement orion picture tube by
PHILIPS 14TVCR240
Memory erase procedure The contents of the memory can only be cleared via the service mode. this option is not available for end users. (risc of destroying option codes). service mode: press "stop" on remote control and "play" on the set for 5 seconds. select the second page
PHILIPS 14TVCR240
Key set The key set assy has been codified for all b-range tvcr's. this will allow to change the keys without having to change the complete frame. servicenr. 4822 410 11069. key set for: 14pv162/01/02/05/07/08/13/58 - 14pv170/05 - 14tvcr240/01n.
PHILIPS 14TVCR240
How to erase memory Press simultanuously buttons rewind, wind and programm (<<, >> and p-) while switching on the power supply. note: correct your service manual on page 1-1-11. the description in the instruction for use is correct.
PHILIPS 14TVCR240
Field collapse Tda3653 replaced
PHILIPS 14TVCR240
Dead, psu not running D6334 ug06b leaky (482213083307)
PHILIPS 14TVCR240
Dead with blurting noise Loptx s/c chs code no p81397
PHILIPS 14TVCR240
Dead D6581 - used by133 in lieu
PHILIPS 14TVCR240
Dead Check start up volts pin 6 tda4605 should be 10v; if low at 3v check ug06b diode d6334 for leak (pt no 4822 130 83307)
PHILIPS 14TVCR240
Damages tapes; eject of cassette with difficulty. Replace kit i (4822 310 31963).
PHILIPS 14TVCR240
Correction partslist In the partslist, 17.734 mhz is mentioned for x-tal pos.1200. this has to be 4.43 mhz. the codenumber 4822 242 81809 is correct. also the specifications of the x-tal on the circuit diagramm on page 1-3-7 is correct.
PHILIPS 14TVCR240
Codenumber information A new software version (ptcp2-7) is available for the control up (ic 7801). service codenumber is 4822 209 15271. this new version is only used in the following sets: 14pv263/01, 14pv162/01, 14pv162/05, 14pv162/07, 14pv163/05, 14pv163/05h, 14pv263/01,
PHILIPS 14TVCR240
Codenumber correction The codenumber (4835 310 57339) in the service manual (see page 1-2-19) for the extension pcb of the mechanism, is wrong.the correct codenumber is 4822 321 62609.
PHILIPS 14TV240/05
Pic missing - sound ok No line dr - q7584 bc637-16 o/c or r3584 47r o/c or d6581 (use 1n4148) leaky
PHILIPS 14TV240/05
No picture - sound ok Ht correct, no line drive; 3584 47r o/c
PHILIPS 14RGR1
Removing hotel mode Press control + & - on ch38
PHILIPS 14PV461
Codenumber information The codenumber for the spacer between on/off switch and the knob (pos 3) is 4822 402 10702
PHILIPS 14PV345/05 TVCR99
No pic tv or pback - sound, osd & txt ok Painter ic saa5562 was not sending correct info to tda8841 jungle chip pin 26 - saa chip faulty
PHILIPS 14PV345/05 TVCR99
Dead at start up with rec led flashing Sus eeprom ic7818 on video board
PHILIPS 14PV330
Dead D6391 byw98/200 in psu s/c