Search: philips
Results: 14238
Make Model Symptom Problem Solution By
PHILIPS 7CM3689
Return lines (retraction). Integrated 7504. * anc *. cold solder on transistor 7304 (loose base). * nov 95 acm *.
PHILIPS 7CM3689
Poor width Capacitor 2424.** diode 6409.**
PHILIPS 7CM3689
Image without definition (focus). Wrong transistor 7307, a bf469 must be used original 2sc3950. * nov 95 acm *.
PHILIPS 7CM3689
Turns off immediately after turning on. Changed transistor 7106. * 26Feb96 anc *.
PHILIPS 7CM3689
Damage IC or TS semiconductor 7101 sub. also 7106.**.
PHILIPS 7CM3689
Brightness does not work Open resistor 3339. * anc *.
PHILIPS 7CM3689
It beeps loudly (power supply), but it doesn't work. Transistor 7106 (bd434) with altered base and emitter junction, little driving. * 26Feb96 anc *.
PHILIPS 7CM3299
No vertical linearity. Check integrated 2511 open. * 20jun97 ctr *.
PHILIPS 7CM3299
Blurred colors Resistors 3370/3366/3340.**.
PHILIPS 7BM749
Vertical running (sync2). Verificar capacitor c422. * 17jan97 fr *.
PHILIPS 7BM749
Fabric oscillates not horizontally. Check capacitor c135 open..
PHILIPS 7BM749
Dark "black" screen (see also bril4). Check resistor r313 incorrect or altered value. * sea 95 jo *. check 3131 open. * 27may96 ctr *.
PHILIPS 7BM749
No vertical sync (vert5). Check adjustment in r422. *01Sep98 h.desk*
PHILIPS 7BM749
Loses sink. hot. when changing scene or resolution. Integrated IC401. *jun 95 is*.
PHILIPS 7BM749
It doesn't work (it stays off). 7104 shorted. *94*. 3102 q104 see r103/r104. does not work, because when turned on the overvoltage occurs, possibility of d109 being on the run. * Dec 94 BC *. check 7101 open. * 11jan96 ctr *. check open resistor 3103. * 04Jul96 ctr *.
PHILIPS 7BM749
Does not open vertically Capacitor c428 aberto. * 25abr96 lav *.
PHILIPS 7BM749
Flickering image (see serr1). Check leaking capacitor 2508. * 13jlu97 fr *.
PHILIPS 7BM749
Turn off inter. or protect (rew 3 for vcr). Check c112 open. * Dec 94 BC *. d109 with escape. * Dec 94 BC *.
PHILIPS 7BM749
Damage IC or TS semiconductor Ic502 damages when turned on, check trc aquadag cable or trc. Note: do not turn on the device without the board shielding trc. grounding point of the trc on the monopanel is parallel to the components r504 and c502, when this symptom is present there is a do
PHILIPS 7BM749
Damages resistor R517, check leaky capacitor c508 (2k7). 05nov96 fr.