Search: sharp
Results: 1784
Make Model Symptom Problem Solution By
SHARP C-20T51
Wobbles and cuts Just gives the fly back's pacifier a quick insult Capacitor de largura c616 8k2 16000v Replace eletroclaudio aguas belas
SHARP 20R11
Just blue screen, the channel doesn't hold tune. It was the q1010-2sc 1815 shorted I replaced it and it went back to normal. eletronica melo boa viagem ,ceará
SHARP C20ST57
Image erases and comes back Replace electrolytic capacitor c725 jefersonpierini
SHARP C20ST57
The picture slows down and then turns off Replacedo capacitor polieter c606 7n5/1600v lpinheiro
SHARP C-20R12
Burning of the r-331 resistor Sound amplifier FERNANDO S
SHARP C-2013
When you plug it into the socket it starts to make popping noises like gunshots C721 variano and leak Replace eletroclaudio aguas belas
SHARP C-20R13
Shaking image TV works normally, when a clearer image appears, it shakes, and when there is no signal, it turns off immediately Replace c669 - put 1μF/100v tiagorech
SHARP C - 2017
White lines at the top of the image C - 657 = 1000uf x 35v FERNANDO S
SHARP C-1485
Power supply beeping and won't turn on C 607 shorted ARAUJO
SHARP TVC 1413/2013
Replace Altered capacitor 712, 39 nano Replace Tectoy
SHARP TVC 1413/2013
Power supply does not weapon Resistor rx717 Replace Tectoy
SHARP C1457B E C2057B
Weak contrast and brightness takes time to appear Capacitor 624 spacious Replace Tectoy
SHARP C1457B E C2057B
Vertical missing at the bottom 1Ω r718 with changed value Replace Tectoy
SHARP C-1453
Does not turn on (arming protection) If it connects without the vertical output, in addition to changing the d603 Bruno
SHARP C-2053
Does not turn on (arming protection) Remove the vertical output ic501 If it connects without the vertical output, in addition to changing the d603 Bruno
SHARP C-20ST58
Turn off after turn on R 505 open This email address is being protected from spambots. You need JavaScript enabled to view it.
SHARP C-1417
Stop Exchange c 719 This email address is being protected from spambots. You need JavaScript enabled to view it.
SHARP C-20ST57
Without image, enlarging the without the image appears but bad C 624 exhausted on the +b of the filament Bruske
SHARP C-20R11
Inoperative, normal voltages, minus the 9 volts that come out of the vertical Zener diode (dz660) shorted This email address is being protected from spambots. You need JavaScript enabled to view it.
SHARP C2041
No contrast. Disconnect pin 3 of the computer. Just that. This email address is being protected from spambots. You need JavaScript enabled to view it.(floripaSC)