Make Model Symptom Problem Solution By
SONY CCDTR84
Eats tapes (found tg4, ref. 765, was bent) Unit would eat tapes. found problem to be caused by tg4, ref.765, being bent.
SONY CCDTR84
No power in cam mode (found dd-80 cn003 loose from vc-167) Unit had no power in camera mode. problem was caused by cn003of the dd-80 board which had come loose from the vc-167 board.
SONY CCDTR84
Lines through picture (found poor soldering of ic201) Customer complaint was lines through picture found camerapicture wad distorted. problem was found to be caused by ic201 on thevc-167 mcb, which was poorly soldered. ic201 is the y/c processor.
SONY CCDTR84
Dead (found loose connections around ic400) Unit was dead. problem was found to be caused by looseconnections around ic400 on the vc-167 mcb.
SONY CCDTR84
No eject (found solder bridge on fp249 shorting sensor h002) Unit would not eject. found problem to be caused by a solderbridge on fp-249 (below the takeup reel). the bridge shorted reelhall sensor h002, preventing any reel pulses from being generated.
SONY CCDTR84
Eats tapes (found tesnsion spring, ref. 783 had come loose) Unit eats tape. problem was found to be caused by tensionspring ref. 783, which had come loose.
SONY CCDTR84
Eats tapes (found tension spring, ref. 781, had come loose) Unit eats tapes. found problem to be caused by tension spring,ref. 781, coming loose.
SONY CCDTR84
Dead (found poor soldering on cn003 on dd-80 mcb) Unit was dead (would not even eject). found problem to be caused by poor soldering of cn003 on the dd-80 mcb.
SONY CCDTR84
Ejects immediately after loading (ref # 752 was dislodged) Immediately after loading a tape, the unit would eject thetape. found that the exit guide, ref. # 752, had come out of the track.
SONY CCDTR84
Won't load tape (found drum would not rotate; replaced drum) Unit would not load tape. found that the drum had a tightspot which prevented it from rotating.
SONY CCDTR84
No rew or review, noise in play (magnet on reel came loose) The unit had no rewind or review. noise could be heard duringplay. found problem to be caused by the magnet on the supply reel comingloose.
SONY CCDTR84
Dead (found loose connector between power mcb & main mcb) The unit was dead found a loose connector between the powerboard and the main board.
SONY CCDTR84
Won't stay in record (found mode switch in wrong position) Unit would not stay in record when the start/stop button waspressed. found that the start/stop mode select switch was set in theposition which allows recordings to be made only while the start/stopswitch is held in. this is an operational feature of th
SONY CCDTR84
Dead (found battery contact j001 on dd-80 mcb cold soldered) Dead. found battery contact j001 on dd-80 mcb was coldsoldered.
SONY CCDTR84
Won't thread (found high tape tension due to ref 769 loose) Unit would not thread tape. found problem to be caused byratchet tension spring (ref. 769) coming dislodged from at the chassisend.
SONY CCDTR83
Int. dead, shut down, lockup (found bad solder on cn203) An asc reported that the unit had intermittent functions, orwould shutdown or lock up. problem was found to be caused by poor solderon cn203.
SONY CCDTR74
Door won't close (mode switch bad, mech did not eject fully) Cassette door would not close, because the mechanism did notfully eject the last time the tape was ejected. found problem to becaused by a faulty mode switch.
SONY CCDTR74
No eject (found tension reg. ref 833 was jammimg ls chassis) The unit would not eject the tape. found problem to be causedby the tension regulator plate which had come loose and was jamming the lschassis.
SONY CCDTR74
Np ff or rew (found tear in fp249) The unit would not rewind or fast forward. found problem tobe caused by unit not sensing movement of the supply reel. this wascaused by a bad conection on fp249, caused by some sort of contact with asharp edge.
SONY CCDTR74
No zoom (found tab which follows worm gear dislodged) Lens would not zoom. after removing the zoom motor found that the inner tab which follows the worm gear on the motor shaft has twisted,preventing proper engagement with the worm gear.