Search: sony
Results: 20100
Make Model Symptom Problem Solution By
SONY MHC-GT5D
Protect 03 Capacitor position 2082 shorted Make the replace Fofão estância
SONY HCD-GPX55
Stopped, dead Coil l504 broken, loose inside the device. Increase the size of the terminals, sand to improve welding and run for the hug! Trendset
SONY KDL-40EX405
It doesn't turn on, the STBY LED lights up and stays green The power supply that went into protection, causes ci cxa3809 24 pins Luir
SONY KDL-32BX305 KDL-40EX405, KDL-40EX715
AZ1
Does not turn on and protection LED is off. defect in power supply g2le, g2he, gd2 IC 3809M-T6 (SixSite09M-T) FTS
SONY KDL-32BX305 KDL-40EX405, KDL-40EX715
AZ1
Goes into protection, LED flashes red twice. defect in power supply g2le, g2he, gd2 IC 3809M-T6 (SixSite09M-T) FTS
SONY KDL-32BX305 KDL-40EX405, KDL-40EX715
AZ1
Doesn't start. defect in power supply g2le, g2he, gd2 IC 3809M-T6 (SixSite09M-T) FTS
SONY KDL-40R485
It turns on normally, when an image with any video signal appears, it turns off and sometimes restarts and the stand by LED does not flash, which could indicate a possible failure. In my case it was due to a failure in the connectors on the rulers, I made the connection with a thin wire between each ruler and its respective point and it solved the problem. Alberi F S
SONY KDL-32R305B
Restarting immediately after turning on Poor contact in the connectors, both on the board and on the bus I cut the connectors and released them straight away, solved carlos eli
SONY KDL-50W655A
Does not turn on, inoperative Short in the v-com smd capacitor (display board) Disconnect the lvds cable from the screen to see if the tv gives a signal of life normally smd capacitor c13 shorted on the v-com -- test the fuse and also the diode Saltech
SONY KDL 32EX425
The TV remains on standby (red LED on) and does not turn on, or if it turns on after a few seconds it turns off. It was bad contact in the cable that connects the main board to the power supply board. I messed with the main board connection and it started working again. Jimi
SONY HCD-EX880Z
Doesn't start Power supply secondary shorted, killing it Chap. elect. 470/16 shorted. davi.sls
SONY KDL-40EX525
Screen with duplicate image Insulated flat pins 1 to 10 Zandro
SONY KDL-32BX425
It turns on normally the first time, if it turns off by itself or if it turns off, it no longer turns on or has a signal from standby, only after 3 days it turns on again, but with the same defect U701 Replaced u701 regulator 3.3 turns work normal. Eletroinfo Ferreira
SONY KDL-40EX605
Reddish image or with lines, normal back light, normal sound and no alerts Banks of open resistors next to the lvds cable connector, check all, set low value, 1r Replace resistor banks Alex Lopes <small>This email address is being protected from spambots. You need JavaScript enabled to view it.</small>
SONY KDL-32EX405
Turns on and off Activates inverter protection Placing an LED from pin 19 to ground disables the protection on the ci ss1091asn
SONY KDL-40EX705
Does not turn on standby LED blinks 2x Smd capacitor c6183 shorted on the power supply board Higorot
SONY KDL-40EX655
Pisca 2x stand-by 1m smd resistors changed When pressing the power button the TV generates 380v in the main capacitor of the power supply and it quickly drops to 170v, check the trigger resistors (tsound are 8 smd resistors in total with a value of 1m each) of the 12v 24v oscillator ci, in my case their values ​​had replaced.
SONY KDL-40EX525
Flashing red screen, duplicated, with lines and bars. Defective panel. In pfc right connector disable tracks vgma13, vgma14, vgma15. electronics supply parts - Gramado/RS
SONY KDL-40W605
All stop inoperative and no LED lights up Fuses on the internal power supply board inside wsound it connects the power supply fuse.9105, f1002, f1001, f2000 and on the PCI.f9101, f9105, f9102 change eletronica publisom de natal rgn
SONY 40EX525
Glitchy and duplicating image. Display with altered sync. On the flat cable of the left tcon between the vcst and vcomg, isolate contact no. 10 from the right to the left, if the image is normal but red, it is a sign that you isolated more than 1 contact, it needs to be a very thin piece of tape preferably kapton. Antony Garcez