Sony Repair Tips
Search: sony
Results: 20072
Results: 20072
Make | Model | Symptom | Problem | Solution | By |
---|---|---|---|---|---|
SONY |
CCDV8
|
Tape jam | Tape jammed. the unit would power up but would not perform any other function. i resoldered x601 and the unit started to perform normally for a few minutes, but it stopped working again. | ||
SONY |
SLHF900
|
Rewind problem | Unit rewinds for approx. 3 to 6 sec then stops (same problemon reverse betascan). problem happened as soon as unit was unpacked. | ||
SONY |
SPP22
|
Hum in head set | There is always a hum present in this and two other similarunits. this hum can be eliminated by moving the lead which connects tothe phone line. placement of this wire is very critical. no solution. -hq comments: connect 0.01/25v cap between the coll | ||
SONY |
STRAV560
|
No fm or am | No fm. | ||
SONY |
SL2710
|
Double picture in pause/poor betascan | In pause mode picture exhibits a bend in the middle and twoimages, slightly offset. betascan was extremely noisy with 2 or 3 noisebars, 15-20 lines wide. symptoms were intermittent. | ||
SONY |
KV25XBR
|
Low brightness | Three units. when using pc701 to interface kv-25xbr to anibm pc, user has washed out picture with low brightness. he claims thishappens with all the pc701s and xbrs he has tried. -hq comments: pc701 reduced somehow overall brightness of whatevermonito | ||
SONY |
KV2649RX
|
Locked in on mode, no manual or remote functions, d021 | Set could only be turned on or off by master switch. noother functions would respond. inspection revealed that a signal wasalways present at pin 37 of ic001. also, at pin 18, same ic, power onsignal present. disconnecting d021 removed the signal pres | ||
SONY |
CFS9000
|
Complete mechanism - p/n missing | Need part number for complete cassette mechanism. -hq comments: the tape transport is not available. | ||
SONY |
CCDV8
|
No video, transport functions ok | No video, but transport functions ok. | ||
SONY |
SL2500
|
Brakes dragging | Brakes would not release. | ||
SONY |
SLHF900
|
No rewind | Unit would go into all forward modes. in rewind or review,the unit would start and go into the stop mode after 3 to 4 seconds.sensor is located on rd-12 board. the board calls out for q001/q002, butthe schematic shows them as diodes d001/d002. either | ||
SONY |
SL2000
|
Unit looses drum lock | Unit would go into a drum loss. about every 5 to 10 seconds,picture would break up. looked like a capstan loose. found ic405 defective. | ||
SONY |
CDP70
|
Unit would not play entire disc | Unit will not track through disc. | ||
SONY |
KV1542R
|
Board add on top of "d" board, same as s/m kv-1742r | Servicer claims that his unit has a small board added abovethe d board. the extra board has 4-5 components including capacitors,resistors and a small transformer. we can find nothing in our documen-tation about it. we need to know what the board is, a | ||
SONY |
CFM15
|
Bad sub for table ass'y, reel | When ordering reel assy (ref 362, p/n x-3302-302-0), wereceived a sub (p/n 3-302-372-02) from kc. this is only a part of thewhole assy. we need the current number for the complete reel assy asshown in the manual. -hq comments: there have been some pro | ||
SONY |
CFS7000
|
Jammed, no eject, no play or record | Removed jammed tape and pieces of head gear, and put in a newone making sure to align fan gear properly. the transport still jammeditself. | ||
SONY |
PSFL9
|
Tonearm drops too quickly | Cue drop not damped. occasionally the tonearm would wobblelaterally on the way down. | ||
SONY |
SLHF400
|
Background noise only, no audio | System noise, no audio in beta hi-fi. | ||
SONY |
KX8200CD
|
No pix, but hi voltage ok, found connector dp-5 off | High voltage would come on but no display, when connected tosmc-70. power on pilot led also dead. | ||
SONY |
KPR4600A
|
No part number for cabinet, not recommened to replace | No part number for cabinet. |